The Prognostic Value of C-reactive Protein to Albumin Ratio in Patients with Isolated Degenerative Aortic Valve Stenosis Undergoing Surgical Aortic Valve Replacement.

Braz J Cardiovasc Surg

University of Health Sciences Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Center Department of Cardiology Istanbul Turkey Department of Cardiology, University of Health Sciences, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Center, Training and Research Hospital, Istanbul, Turkey.

Published: June 2020

Objective: To evaluate the prognostic value of C-reactive protein to albumin ratio (CAR) in patients with severe aortic valve stenosis undergoing surgical aortic valve replacement (AVR).

Methods: Four hundred seventy-six patients with severe degenerative aortic stenosis who underwent successful isolated surgical AVR were enrolled. Hospitalization due to heart failure, surgical aortic reoperation, paravalvular leakage rates, and long-term mortality were evaluated in the whole study group. The participants were divided into two groups, as 443 patients without mortality (group 1) and 33 patients with mortality (group 2) during the follow-up time.

Results: CAR was lower in patients without mortality than in those with mortality during the follow-up time (0.84 [0.03-23.43] vs. 2.50 [0.22-26.55], respectively, P<0.001). Age (odds ratio [OR]: 1.062, confidence interval [CI]: 1.012-1.114, P=0.014), CAR (OR: 1.221, CI: 1.125-1.325, P<0.001), ejection fraction (OR: 0.956, CI: 0.916-0.998, P=0.042), and valve type (OR: 2.634, CI: 1.045-6.638, P=0.040) were also found to be independent predictors of long-term mortality. Additionally, rehospitalization (0.86 [0.03-26.55] vs. 1.6 [0.17-24.05], P=0.006), aortic reoperation (0.87 [0.03-26.55] vs. 1.6 [0.20-23.43], P=0.016), and moderate to severe aortic paravalvular leakage (0.86 [0.03-26.55] vs. 1.86 [0.21-19.50], P=0.023) ratios were associated with higher CAR.

Conclusion: It was firstly described that CAR was strongly related with increased mortality rates in patients with isolated severe aortic stenosis after surgical AVR. Additionally, rehospitalization, risk of paravalvular leakage, and aortic reoperation rates were higher in patients with increased CAR than in those without it.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7299583PMC
http://dx.doi.org/10.21470/1678-9741-2019-0114DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
surgical aortic
12
patients mortality
12
prognostic c-reactive
8
c-reactive protein
8
protein albumin
8
albumin ratio
8
degenerative aortic
8
valve stenosis
8
stenosis undergoing
8

Similar Publications

One-year hemodynamic and clinical outcomes in self-expanding valves: Comparison of ACURATE neo2 versus ACURATE neo.

Cardiovasc Revasc Med

December 2024

Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:

Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.

View Article and Find Full Text PDF

Lower mini-sternotomy: an approach for treating all valvulopathies?

Ann Thorac Surg

December 2024

Sorbonne University, Department of Cardiovascular and Thoracic Surgery, Institute of Cardiology, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.

Background: Lower mini-sternotomy offers the advantage of providing excellent visualization of the 4 cardiac cavities, allowing surgical treatment of aortic, mitral and tricuspid valves as well as any intra-cavitary procedure. Technical issues, as well as safety and echocardiographic results of this approach, are lacking. The aim of this retrospective study was to describe outcomes of lower mini-sternotomy to treat valvulopathies and other intracardiac surgeries.

View Article and Find Full Text PDF

Is connective tissue disorder a risk factor for durability after valve-sparing root replacement?

Semin Thorac Cardiovasc Surg

December 2024

Aortic Center, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH. Electronic address:

View Article and Find Full Text PDF

Background: Interleaflet haemorrhage (IH) plays a well-recognized detrimental role in calcified aortic valve disease (CAVD). However, IH-induced fibro-osteogenic responses in valvular interstitial cells (VICs) appear to be triggered under specific pathological conditions. Iron deficiency (ID), a common co-morbidity in CAVD, may influence these responses.

View Article and Find Full Text PDF

Aortitis, defined as inflammation of the aorta, can lead to aneurysms and dissections. Intra-operative sampling is essential for diagnosis, with many cases presenting asymptomatically as clinically isolated aortitis. Previous studies investigating aortitis in major aortic surgery have been limited by low intra-operative sampling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!