EEG signal processing is a fundamental method for neurophysiology research and clinical neurology practice. Historically the classification of EEG into physiological, pathological, or artifacts has been performed by expert visual review of the recordings. However, the size of EEG data recordings is rapidly increasing with a trend for higher channel counts, greater sampling frequency, and longer recording duration and complete reliance on visual data review is not sustainable. In this study, we publicly share annotated intracranial EEG data clips from two institutions: Mayo Clinic, MN, USA and St. Anne's University Hospital Brno, Czech Republic. The dataset contains intracranial EEG that are labeled into three groups: physiological activity, pathological/epileptic activity, and artifactual signals. The dataset published here should support and facilitate training of generalized machine learning and digital signal processing methods for intracranial EEG and promote research reproducibility. Along with the data, we also propose a statistical method that is recommended for comparison of candidate classifier performance utilizing out-of-institution/out-of-patient testing.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7297990 | PMC |
http://dx.doi.org/10.1038/s41597-020-0532-5 | DOI Listing |
MethodsX
June 2025
Medical College of Wisconsin, Department of Neurosurgery, 8701 Watertown Plank Road, Milwaukee, WI, 53226.
Electrographic recording of brain activity through either surface electrodes (electroencephalography, EEG) or implanted electrodes (electrocorticography, ECOG) are valuable research tools in neuroscience across many disciplines, including epilepsy, sleep science and more. Research techniques to perform recordings in rodents are wide-ranging and often require custom parts that may not be readily available. Moreover, the information required to connect individual components is often limited and can therefore be challenging to implement.
View Article and Find Full Text PDFJ Clin Neurophysiol
December 2024
Human Brain Mapping Program, University of Pittsburgh Medical Centre, Pittsburgh, Pennsylvania, U.S.A.; and.
Objectives: Our study aimed to compare signal characteristics of subdural electrodes (SDE) and depth stereo EEG placed within a 5-mm vicinity in patients with drug-resistant epilepsy. We report how electrode design and placement collectively affect signal content from a shared source between these electrode types.
Methods: In subjects undergoing invasive intracranial EEG evaluation at a surgical epilepsy center from 2012 to 2018, stereo EEG and SDE electrode contacts placed within a 5-mm vicinity were identified.
Alzheimers Dement
December 2024
Latin American Brain Health Institute (BrainLat), Universidad Adolfo Ibáñez, Santiago, Región Metropolitana, Chile.
Background: The human brain integrity relies on the synergistic interplay between neural activity and supporting vascular and metabolic processes throughout life. This relationship, ruled by allostatic mechanisms, regulates brain architecture and activity. White matter hyperintensities (WMH) serve as indicators of the vascular impact on brain structure.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
Latin American Brain Health Institute (BrainLat), Universidad Adolfo Ibáñez, Santiago, Región Metropolitana, Chile.
Background: The human brain integrity relies on the synergistic interplay between neural activity and supporting vascular and metabolic processes throughout life. This relationship, ruled by allostatic mechanisms, regulates brain architecture and activity. White matter hyperintensities (WMH) serve as indicators of the vascular impact on brain structure.
View Article and Find Full Text PDFSurg Neurol Int
December 2024
Department of Neurosurgery, University of California, Irvine, Orange, United States.
Background: Stereoelectroencephalography (SEEG) is a common diagnostic surgical procedure for patients with medically refractory epilepsy. We aimed to describe our initial experience with the recently released NeuroOne Evo SEEG electrode product (Zimmer Biomet, Warsaw, IN) and review technical specifications for other currently approved depth SEEG electrodes.
Methods: We performed a record review on the first five patients implanted with NeuroOne Evo SEEG electrode product using the robotic stereotactic assistance robot platform and described our surgical technique in detail.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!