A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

First clinical multicenter experience with the new Scepter Mini microballoon catheter. | LitMetric

Background: Balloon-assisted techniques can improve the endovascular treatment of cerebrospinal vascular malformations. The aim of this study was to report the first clinical multicenter experience with the new Scepter Mini dual-lumen microballoon catheter.

Methods: Patients with cerebral or spinal vascular malformations treated with the Scepter Mini at seven European neurovascular centers were retrospectively reviewed. Clinical data, angiographic features of the vascular malformations, procedural parameters including the type of application, navigability, technical failures, complications and embolization success were assessed.

Results: The usage of 34 Scepter Mini microballoon catheters in 20 patients was analyzed. Most treated malformations (80.0%) were cerebral arteriovenous malformations. Four different applications were reported: embolization via Scepter Mini (n=23, 67.6%), balloon-occlusion with simultaneous embolization via a second microcatheter (n=3, 8.8%), diagnostic angiography with simultaneous balloon-inflation for flow arrest (n=4, 11.8%), and navigation support (n=4, 11.8%). The mean diameter of the blood vessels in which the Scepter Mini was inflated was 1.9±0.5 mm. The navigability of the Scepter Mini was rated as 'easy' or 'very easy' in 88.2% of cases. Complete occlusion of the malformation was achieved in 60.9% of cases. Technical failures occurred in 4/23 embolization procedures, and all were related to insufficient stability of the balloon within the vessel. No complications related to the Scepter Mini were observed, while unrelated complications occurred in three patients (15.0%).

Conclusions: The Scepter Mini is a promising new device for balloon-assisted embolization of cerebrospinal vascular malformations via small feeders. Beyond embolization, the Scepter Mini can also be used for other applications, such as superselective flow arrest and navigation support.

Download full-text PDF

Source
http://dx.doi.org/10.1136/neurintsurg-2020-016115DOI Listing

Publication Analysis

Top Keywords

scepter mini
40
vascular malformations
16
scepter
10
mini
10
clinical multicenter
8
multicenter experience
8
experience scepter
8
mini microballoon
8
cerebrospinal vascular
8
technical failures
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!