A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experimental Model of Zygomatic and Mandibular Defects to Support the Development of Custom Three-Dimensional--Printed Bone Scaffolds. | LitMetric

Introduction: Autologous reconstruction of segmental craniomaxillofacial bone defects is limited by insufficient graft material, donor site morbidity, and need for microsurgery. Reconstruction is challenging due to the complex three-dimensional (3D) structure of craniofacial skeleton. Customized 3D-printed patient-specific biologic scaffolds hold promise for reconstruction of the craniofacial skeleton without donor site morbidity. The authors report a porcine craniofacial defect model suitable for further evaluation of custom 3D-printed engineered bone scaffolds.

Methods: The authors created a 6 cm critical load-bearing defect in the left mandibular angle and a 1.5 cm noncritical, nonload bearing defect in the contralateral right zygomatic arch in 4 Yucatan minipigs. Defects were plated with patient-specific titanium hardware based on preoperative CT scans. Serial CT imaging was done immediately postoperatively, and at 3 and 6 months. Animals were clinically assessed for masticatory function, ambulation, and growth. At the 6-month study endpoint, animals were euthanized, and bony regeneration was evaluated through histological staining and micro-CT scanning compared to contralateral controls.

Results: All 4 animals reached study endpoint. Two mandibular plates fractured, but did not preclude study completion due to loss of masticatory function. One zygoma plate loosened while the site of another underwent heterotopic ossification. Gross examination of site defects revealed heterotopic ossification, confirmed by histological and micro-CT evaluation. Biomechanical testing was unavailable due to insufficient bony repair.

Conclusions: The presented porcine zygoma and mandibular defect models are incapable of repair in the absence of bone scaffolds. Based on the authors' results, this model is appropriate for further study of custom 3D-printed engineered bone scaffolds.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0000000000006647DOI Listing

Publication Analysis

Top Keywords

bone scaffolds
12
donor site
8
site morbidity
8
craniofacial skeleton
8
custom 3d-printed
8
3d-printed engineered
8
engineered bone
8
masticatory function
8
study endpoint
8
heterotopic ossification
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!