AI Article Synopsis

  • The erratum addresses a mistake in the calculations related to the fluence of pulsed laser used for exciting nanoparticles.
  • It corrects previously reported data in the original paper published in 2019.
  • The updated findings also revise the conclusions about the laser safety limits when using this excitation method.

Article Abstract

We present an erratum to correct an inadvertent error made during the calculations of the in-focus fluence of pulsed laser used to excite nanoparticles [Opt. Lett.44, 3162 (2019)OPLEDP0146-959210.1364/OL.44.003162] and to update the conclusion regarding laser safety limits achieved with this type of excitation.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.398141DOI Listing

Publication Analysis

Top Keywords

longitudinal elastic
4
elastic wave
4
wave imaging
4
imaging nanobomb
4
nanobomb optical
4
optical coherence
4
coherence elastography
4
elastography erratum
4
erratum erratum
4
erratum correct
4

Similar Publications

Background: Little is known about the determinants of disease progression among African patients with chronic HBV infection.

Methods: We used machine-learning models with longitudinal data to establish predictive algorithms in a well-characterized cohort of Ethiopian HBV-infected patients without baseline liver fibrosis. Disease progression was defined as an increase in liver stiffness to >7.

View Article and Find Full Text PDF

: The association between diabetic nephropathy and arterial elasticity and endothelial function is well established. In this study, we compared the effect of the combination of dulaglutide and dapagliflozin versus DPP-4 inhibitors on the endothelial glycocalyx, arterial stiffness, myocardial function, and albuminuria. : Overall, 60 patients were randomized to combined dulaglutide and dapagliflozin treatment (n = 30) or DPP-4 inhibitors (DPP-4i, n = 30) (ClinicalTrials.

View Article and Find Full Text PDF

Mechanical properties of the bicipital aponeurosis.

J Mech Behav Biomed Mater

December 2024

School of Engineering, University of Guelph, Guelph, Ontario, Canada. Electronic address:

As a biarticular muscle, the biceps brachii both supinates the forearm and flexes the elbow and shoulder, thus allowing the upper limb to perform a variety of activities of daily living (ADL). The biceps brachii originates on the coracoid apex as well as the supraglenoid tubercle and inserts on the radial tuberosity. At the distal end, the bicipital aponeurosis (BA) provides a transition of the biceps tendon into the antebrachial fascia.

View Article and Find Full Text PDF

Non-invasive pressure-volume loop derived temporal elastance, contractility, and efficiency indices for assessing Duchenne muscular dystrophy patients.

Heart Vessels

December 2024

Department of Biomedical Engineering, Veterans Affairs Medical Center, University of Cincinnati, Rhodes Hall 593, 2851 Woodside Drive, Cincinnati, OH, 45219, USA.

Ejection fraction is commonly used to assess Duchenne muscular dystrophy-associated cardiomyopathy (DMDAC), but it may remain normal (wrongly) despite significant myocardial dysfunction in patients. Therefore, better indicators of myocardial dysfunction are needed for longitudinal (with time) assessment and treatment of DMDAC patients. This study evaluates non-invasive LV PV loop-derived elastance, contractility and efficiency in relation to EF for patients developing DMDAC.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!