There is some consensus that endometrial thickness (EMT) needs to be at least 7 mm on day of embryo transfer. However, the predictive role of baseline EMT and EMT change in response to estrogen is largely unknown. The objective of this study was to evaluate the role of endometrial thickness in frozen embryo transfer (FET) cycles. We analyzed the association of baseline endometrial thickness (EMTb-Day 3 of cycle) and endometrial thickness change (EMTΔ-from baseline to start of progesterone supplementation) with FET success in 121 cycles. We also investigated whether baseline estradiol levels and body mass index (BMI) are associated with EMTb. No difference was observed in EMTb and EMTΔ in cycles resulting in clinical pregnancy compared to unsuccessful transfers (5.1 ± 2.2 mm vs 5.0 ± 1.9 mm; p = 0.92, and 4.7 ± 2.4 mm vs. 4.4 ± 2.4 mm; p = 0.56). When 7 mm cut-off was used, endometrial thickness on the day of start of progesterone supplementation (EMTp) was also not different between groups (9.8 ± 2.9 mm vs. 9.4 ± 2.5 mm; p = 0.50). Multivariable logistic regression models did not demonstrate any predictive value of EMTb, EMTp, or EMTΔ in predicting success of FET cycles (p = 0.92, p = 0.80, and p = 0.84, respectively). There was no significant correlation between EMTb and baseline estradiol levels (r = -0.001; p = 0.985). BMI showed statistically significant weak positive linear relationship with EMTb (r = +0.29; p = 0.002). Our study did not demonstrate any significant relationship between baseline endometrial thickness or endometrial thickness change and clinical pregnancy rates in frozen embryo transfer cycles. Significant positive linear relationship of BMI with baseline endometrial thickness, despite no correlation between baseline estradiol and EMTb, points to the role of possible other mechanism affecting EMT besides estradiol in obese patients.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s43032-020-00233-3DOI Listing

Publication Analysis

Top Keywords

endometrial thickness
40
baseline endometrial
16
embryo transfer
16
thickness change
12
frozen embryo
12
baseline estradiol
12
thickness
10
baseline
9
endometrial
9
thickness endometrial
8

Similar Publications

Objective: To compare pregnancy outcomes and serum progesterone levels between women who took sublingual (SL) progesterone lozenges versus intramuscular (IM) progesterone-in-oil for endometrial preparation and luteal support in programmed frozen embryo transfer (pFET) cycles.

Design: Retrospective cohort study.

Subjects: All patients who underwent pFET of a single euploid good-quality blastocyst between January 2018 and April 2023 at a single fertility center.

View Article and Find Full Text PDF

Ovarian sex cord-stromal cell tumors and the risk of sex hormone-sensitive cancers.

Am J Obstet Gynecol

January 2025

Women's Health, Aabenraa, University Hospital of Southern Denmark; Institute of Regional Health Research, University of South Denmark.

Background: Sex cord-stromal cell tumors (SCST) are rare tumors of the ovary. Some of the SCSTs secrete hormone originating from the sex or stromal cell of the ovaries. Previous studies have indicated an increased risk of breast and endometrial cancers.

View Article and Find Full Text PDF

Aim: The present study was conducted to analyze uterine measurements and endometrial thickness throughout the menstrual cycle in Saudi healthy females of reproductive age.

Methods: This cohort study was conducted at Princess Nourah bint Abdulrahman University, Saudi Arabia, among thirty-three females of reproductive age who underwent trans-abdominal pelvic ultrasound scans across four menstrual cycle phases. Data analysis was conducted using SPSS version 26, utilizing descriptive statistics, one-way ANOVA, correlation, and regression analysis.

View Article and Find Full Text PDF

Background: Endometriosis is a gynecologic disorder which causes dysmenorrhea and infertility. Early diagnosis of endometriosis can help prevent the necessity for invasive diagnostic procedures. Medical imaging has been widely utilized to diagnose various diseases without the need for invasive procedures.

View Article and Find Full Text PDF

Application of narrow-band imaging combined with hysteroscopic 7Fr cold knife in the treatment of missed early miscarriage.

Arch Gynecol Obstet

January 2025

Department of Gynecology, Maternal and Child Health Hospital of Hubei Province, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430070, China.

Purpose: The application of narrow-band imaging for missed early miscarriage treatment remains unclear. This study determined the application advantages of NBI combined with hysteroscopic 7Fr cold knife embryo removal for treating missed early miscarriage.

Methods: A retrospective selection of 208 patients who were hospitalized for missed early miscarriage at Hubei Provincial Maternal and Child Health Hospital from January 2023 to June 2023 were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!