The complex environment within a crop canopy leads to a high variability of the air temperature within the canopy, and, therefore, air temperature measured at a weather station (WS) does not represent the internal energy within a crop. The objectives of this study were to quantify the difference between the air temperature measured at a standard WS and the air temperature within a six-year-old vineyard (cv. Chardonnay) and to determine the degree of uncertainty associated with the assumption that there is no difference between the two temperatures when air temperature is used as input in grapevine models. Thermistors and thermocouples were installed within the vine canopy at heights of 0.5 m and 1.2 m above the soil surface and immediately adjacent to the berry clusters. In the middle of the clusters sensors were installed to determine the temperature of the air surrounding the clusters facing east and west. The data were recorded within the canopy from December 2015 to June 2017 as well as at the standard WS that was installed close to the vineyard (410 m). Significant differences were found between the air temperatures measured at the WS and those within the vineyard during the summer when the average daily minimum air temperature within the canopy was 1.2°C less than at the WS and the average daily maximum air temperature in the canopy was 2.0°C higher than at the WS. The mean maximum air temperature measured in the clusters facing east was 1.5°C higher and west 4.0°C higher than the temperature measured at the WS. Therefore, models that assume that air temperature measured at a weather station is similar to air temperature measured in the vineyard canopy could have greater uncertainty than models that consider the temperature within the canopy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7289347 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0234436 | PLOS |
J Anim Physiol Anim Nutr (Berl)
January 2025
Botany Department, Faculty of Science, Fayoum University, Fayoum, Egypt.
In tropical and subtropical countries like Egypt, sheep breeding faces environmental thermal stress, especially during the summer when air temperature and humidity are very high. Using Microalgae as an alternative feedstuff can significantly improve sheep growth, health and oxidative status. Therefore, this study aimed to evaluate the effect of consuming two different species of microalgae: Spirulina platensis (SP) and Chlorella vulgaris (C.
View Article and Find Full Text PDFSci Rep
January 2025
Young Researchers and Elite Club, Omidiyeh Branch, Islamic Azad University, Omidiyeh, Iran.
Accurate estimation of interfacial tension (IFT) between nitrogen and crude oil during nitrogen-based gas injection into oil reservoirs is imperative. The previous research works dealing with prediction of IFT of oil and nitrogen systems consider synthetic oil samples such n-alkanes. In this work, we aim to utilize eight machine learning methods of Decision Tree (DT), AdaBoost (AB), Random Forest (RF), K-nearest Neighbors (KNN), Ensemble Learning (EL), Support Vector Machine (SVM), Convolutional Neural Network (CNN) and Multilayer Perceptron Artificial Neural Network (MLP-ANN) to construct data-driven intelligent models to predict crude oil - nitrogen IFT based upon experimental data of real crude oils samples encountered in underground oil reservoirs.
View Article and Find Full Text PDFSci Rep
January 2025
College of Art and Design, Sichuan Tourism University, No.459, Hongling Road, Longquanyi District, Chengdu City, 610100, Sichuan Province, China.
The Maisotsenko cycle-based coolers have gained increasing attention in recent years due to their advantages of low energy consumption and environmental friendliness. Optimizing the model structure and operating conditions is the primary approach for enhancing the cooling performance of dew-point evaporation systems. In this paper, a novel mathematical model of the perforated dew-point evaporative cooler was developed to investigate its cooling performance.
View Article and Find Full Text PDFSci Rep
January 2025
Innovation Institute for Sustainable Maritime Architecture Research and Technology, Qingdao University of Technology, Qingdao, 266033, People's Republic of China.
During the hot summer months, the significant temperature disparity between outdoor and indoor air-conditioned spaces can lead to thermal discomfort and pose a potential health risk. Transition areas such as corridors and elevator lobbies, serving as intermediary zones connecting indoors and outdoors, have been found effective in mitigating this thermal discomfort. In this study, three different temperatures (25 °C-case 1, 27 °C-case 2, and 29 °C-case 3) were employed to investigate the dynamic physiological regulation and thermal perception response of individuals when transitioning from an outdoor environment into an indoor neutral room through a transition space.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Physical Education, States University of Pará, Pará, Brazil.
It is well known that elite athletes of specific ethnicities and/or nationalities dominate certain sports disciplines (e.g., East Africans in marathon running).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!