Background: Electrical impedance technology has been well established for the last 20 years. Recently research has begun to emerge into its potential uses in the detection and diagnosis of pre-malignant and malignant conditions. The aim of this study was to systematically review the clinical application of electrical impedance technology in the detection of malignant neoplasms.
Methods: A search of Embase Classic, Embase and Medline databases was conducted from 1980 to 22/02/2018 to identify studies reporting on the use of bioimpedance technology in the detection of pre-malignant and malignant conditions. The ability to distinguish between tissue types was defined as the primary endpoint, and other points of interest were also reported.
Results: 731 articles were identified, of which 51 reported sufficient data for analysis. These studies covered 16 different cancer subtypes in a total of 7035 patients. As the studies took various formats, a qualitative analysis of each cancer subtype's data was undertaken. All the studies were able to show differences in electrical impedance and/or related metrics between malignant and normal tissue.
Conclusions: Electrical impedance technology provides a novel method for the detection of malignant tissue, with large studies of cervical, prostate, skin and breast cancers showing encouraging results. Whilst these studies provide promising insights into the potential of this technology as an adjunct in screening, diagnosis and intra-operative margin assessment, customised development as well as multi-centre clinical trials need to be conducted before it can be reliably employed in the clinical detection of malignant tissue.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7282098 | PMC |
http://dx.doi.org/10.1186/s12967-020-02395-9 | DOI Listing |
Mikrochim Acta
January 2025
Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
Carcinoembryonic antigen (CEA) and C-reactive protein (CRP) are biomacromolecules known as cancer and inflammatory markers. Thus, they play a crucial role in early cancer diagnosis, post-treatment recurrence detection, and tumor risk assessment. This paper describes the development of an ultrasensitive and selective imprinted paper-based analytical device (PAD) as impedance sensor for determination of CEA and CRP in serum samples for point-of-care testing (POCT).
View Article and Find Full Text PDFAnnu Rev Chem Biomol Eng
January 2025
Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, Norrköping, Sweden; email:
Organic mixed ionic-electronic conductors (OMIECs) could revolutionize bioelectronics by enabling seamless integration with biological systems. This review explores their role in neural biomimicry and biointerfacing, with a focus on how backbone design, sidechain optimization, and antiambipolarity impact performance. Recent advances highlight OMIECs' biocompatibility and mechanical compliance, making them ideal for bioelectronic applications.
View Article and Find Full Text PDFCien Saude Colet
January 2025
Escola Nacional de Saúde Pública, Fundação Oswaldo Cruz. Rio de Janeiro RJ Brasil.
The scope of this study was to determine the diagnostic performance of ABSI for obesity and sarcopenic obesity, compared to the results of bioimpedance analysis (BIA) and BMI, by sex and age group. It involved a cross-sectional study with 12,793 participants in the second round of ELSA-Brasil (Longitudinal Study of Adult Health in Brazil), which obtained measurements of body fat percentage using BIA and anthropometry, verifying the performance of the diagnostic tests in order to compare the indices. The results showed that for obesity in men in all three age groups, the sensitivity was below 49%.
View Article and Find Full Text PDFTrop Biomed
December 2024
Department of Critical Care Medicine, The Fourth Affiliated Hospital, School of Medicine, Zhejiang University, No. N1 Shangcheng Avenue, Yiwu, Zhejiang 322000, China.
Scrub typhus is an infectious disease caused by Orientia tsutsugamushi. It is transmitted through bite of chigger mite larvae and presents with symptoms such as fever, myalgia, headache, rash, and a characteristic eschar at the site of mite bites. This report details the case of a woman exhibiting acute febrile illness, bilateral pneumonia, and severe hypoxemia, prompting suspicion of scrub typhus due to the presence of a typical eschar on the pubic mound.
View Article and Find Full Text PDFNat Commun
January 2025
Department of Biomedical Engineering, State University of New York at Binghamton, Binghamton, NY, 13902, USA.
Creating durable, motion-compliant neural interfaces is crucial for accessing dynamic tissues under in vivo conditions and linking neural activity with behaviors. Utilizing the self-alignment of nano-fillers in a polymeric matrix under repetitive tension, here, we introduce conductive carbon nanotubes with high aspect ratios into semi-crystalline polyvinyl alcohol hydrogels, and create electrically anisotropic percolation pathways through cyclic stretching. The resulting anisotropic hydrogel fibers (diameter of 187 ± 13 µm) exhibit fatigue resistance (up to 20,000 cycles at 20% strain) with a stretchability of 64.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!