Study Objective: Several studies have been published on hysteroscopic treatment of cesarean scar defect using the 26 Fr resectoscope. This study compared the effects of the 26 Fr resectoscope with those of the 16 Fr mini-resectoscope in terms of efficacy, safety profile, and peri- and postoperative complications.
Design: A prospective cohort study.
Setting: Tertiary care university hospital (S. Orsola-Malpighi, Bologna, Italy).
Patients: Three hundred and nine women having symptoms and with a cesarean scar defect diagnosis were divided into 2 groups according to a temporal criterion: from March 2012 to March 2015, 155 consecutive women (control group) underwent isthmoplasty with the 26 Fr resectoscope (Karl Storz, Tuttlingen, Germany), whereas from April 2015 to March 2018, 154 consecutive women (study group) underwent isthmoplasty with the 16 Fr mini-resectoscope (Gubbini system, Tontarra Medizintechnik, Tuttlingen, Germany).
Interventions: One hundred and fifty-five women (control group) underwent isthmoplasty with the 26 Fr resectoscope, and 154 women (study group) underwent isthmoplasty with the 16 Fr mini-resectoscope. The so-called "channel-like" 360° endocervical resection technique was applied.
Measurements And Main Results: The isthmoplasty time with the 2 resectoscopes, excluding cervical dilatation, was similar (p = .25), whereas the overall surgical time was shorter in the case of the mini-resectoscope. The use of the 16 Fr mini-resectoscope was significantly associated with a reduced volume of distension medium used (p <.001) and a lower fluid absorption (p <.001). A significant increase (p = .01) in postoperative complications in the control group (9/155; 5.8%) compared with the study group (1/154; 0.7%) was also found. No significant reduction in discharge time was observed between the 2 groups (p = .13). Patient satisfaction immediately after surgery was significantly higher (p <.001) in the study group than in the control group.
Conclusion: Isthmoplasty with a 16 Fr mini-resectoscope seems to be as effective as isthmoplasty with a 26 Fr resectoscope in reducing postmenstrual abnormal uterine bleeding and suprapubic pelvic pain. It is associated with a significant reduction in overall surgical time owing to the non-necessity of performing cervical dilatation. The 16 Fr mini-resectoscope facilitates surgery in small anatomical spaces such as the cervical canal and reduces the complication rate linked to blind maneuvers not respecting the uterine anatomy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jmig.2020.06.002 | DOI Listing |
Am J Sports Med
January 2025
Midwest Orthopaedics at Rush University Medical Center, Chicago, Illinois, USA.
Background: Mismatch between osteochondral allograft (OCA) donor and recipient sex has been shown to negatively affect outcomes. This study accounts for additional donor variables and clinically relevant outcomes.
Purpose: To evaluate whether donor sex, age, donor-recipient sex mismatch, and duration of graft storage affect clinical outcomes and failure rates after knee OCA transplantation.
Am J Sports Med
January 2025
Section of Young Adult Hip Surgery, Division of Sports Medicine, Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.
Background: Many studies have examined the prevalence of acetabular version (AV) and femoral version (FV) abnormalities and their effect on patient-reported outcomes (PROs) after hip arthroscopy for femoroacetabular impingement syndrome (FAIS), but few have explored the prevalence and influence of combined version (CV) abnormalities.
Purpose: To (1) describe the distribution of AV, FV, and CV in the largest cohort to date and (2) determine the relationship between AV, FV, and CV and PROs after hip arthroscopy for FAIS.
Study Design: Cohort study; Level of evidence, 3.
Am J Sports Med
January 2025
Department of Orthopaedic Surgery, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul, South Korea.
Background: Studies are still limited on the isolated effect of retear after arthroscopic rotator cuff repair (ARCR) on functional outcomes after the midterm period.
Purpose: To assess the effect of retear at midterm follow-up after ARCR and to identify factors associated with the need for revision surgery.
Study Design: Cohort study; Level of evidence, 3.
Sci Rep
January 2025
Department of Gastroenterology, Jiangxi Provincial Key Laboratory of Digestive Diseases, Jiangxi Clinical Research Center for Gastroenterology, Digestive Disease Hospital, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, China.
Fever is a complication after colorectal endoscopic submucosal dissection (ESD). The objective of this study was to explore the incidence and risk factors of fever after colorectal ESD and establish a predictive nomogram model. This retrospective analysis encompassed patients with colorectal lesions who underwent ESD between June 2008 and December 2021 in our center.
View Article and Find Full Text PDFJ Robot Surg
January 2025
Department of Pediatric Anesthesia and Intensive Care, Necker-Enfants Malades University Hospital, AP-HP Centre, Université Paris Cité, 149, Rue de Sèvres 75015, Paris, France.
Retroperitoneal robotic-assisted laparoscopic pyeloplasty (R-RALP) is the commonest urologic procedure performed in children, entailing retroperitoneal CO2 insufflation and lateral decubitus, whose effects on cardiopulmonary variables are poorly known. We, therefore, studied hemodynamic and respiratory changes due to CO2 insufflation and lateral decubitus in children undergoing R-RALP and their effects on regional tissue oxygenation. Between 1/2021 and 7/2024, children affected by ureteropelvic joint obstruction (UPJO) underwent a pyeloplasty by R-RALP at Necker Enfants Malades Hospital (Paris, France), using a standardized surgical technique and a lung-protecting anesthetic protocol aimed to prevent hypercarbia.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!