Median sternotomy has been used to aide thyroidectomies demonstrating good outcomes; however no cases have been documented to show the use of mini-sternotomy to perform simultaneous thyroidectomy and valve surgery. We present a novel case of an 83-year-old woman with severe aortic stenosis and retrosternal goitre extending to the aortic arch deemed unsuitable for TAVI. Due to co-morbid status and anatomical position preventing routine thyroidectomy, we elected to perform a combined procedure to excise the goitre and perform an aortic valve replacement through a mini-J sternotomy, utilizing 3D-reconstructed imaging to plan our approach. This case shows that mini-sternotomy is a safe and effective method to perform concomitant thyroidectomy and aortic valve surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7263760 | PMC |
http://dx.doi.org/10.1093/jscr/rjaa066 | DOI Listing |
Heart Rhythm O2
December 2024
Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer Sheva, Israel.
Background: Transcatheter aortic valve replacement (TAVR) has revolutionized the management of aortic stenosis and has become the standard of care across a broad spectrum of patients with aortic stenosis. However, it is still associated with high incidence of conduction abnormalities, particularly new left bundle branch block (LBBB). Management of these patients remains a challenge.
View Article and Find Full Text PDFCase Rep Cardiol
January 2025
Department of Medicine, Division of Cardiology, University of Washington, Seattle, Washington, USA.
Anomalous aortic origin of a coronary artery is a rare congenital heart defect. The detection of anomalous coronary arteries is likely to increase with increased availability and application of cardiac computed tomography and magnetic resonance imaging. Once detected, the recommendation for surgical intervention on anomalous coronary arteries depends upon patient symptoms, the presence or absence of inducible ischemia on stress imaging, and high-risk anatomic features.
View Article and Find Full Text PDFCureus
December 2024
Internal Medicine, Hospital Universitario Dr. José Eleuterio González, Monterrey, MEX.
Heyde's syndrome is a clinical entity that combines aortic stenosis, gastrointestinal angiodysplasia, and an acquired von Willebrand factor disorder. This syndrome is characterized by the association between aortic stenosis and recurrent gastrointestinal bleeding episodes, typically linked to angiodysplasias. Effective treatment requires addressing the underlying condition, specifically aortic stenosis, which leads to the structural destruction of coagulation proteins, resulting in the acquired von Willebrand factor disorder and perpetuating the bleeding.
View Article and Find Full Text PDFJACC Asia
December 2024
Department of Cardiology, National Heart Centre Singapore, Singapore.
Transcatheter aortic valve implantation (TAVI) has been established as an effective treatment modality in patients with severe aortic stenosis (AS) and the uptake of TAVI is rapidly growing in the Asia-Pacific region. However, there exist a heterogeneity in the management of aortic stenosis and the use of TAVI among countries in the region. Reasons for these differences include anatomic variations, disparity in healthcare resources and infrastructure, and the lack of consensus on the optimal management of AS in the Asia-Pacific region.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiology, Komaki City Hospital, 1-20 Joubushi, Komaki, Aichi 485-8520, Japan.
Background: Transcatheter aortic valve implantation (TAVI) is a safe and effective therapy for patients with severe aortic stenosis. A Stuck leaflet and severe intraprosthetic regurgitation after valve implantation occur rarely but can lead to sudden haemodynamic deterioration. We encountered a case of a stuck leaflet following post-dilatation with the Edwards Sapien 3 Ultra RESILIA valve.