Short-Term Effect of Different Taping Methods on Local Skin Temperature in Healthy Adults.

Front Physiol

Department of Rehabilitation, School of International Medical Technology, Shanghai Sanda University, Shanghai, China.

Published: May 2020

Background: There were limited studies on the effect of skin temperature and local blood flow using kinesio tape (KT) adhered to the skin in different taping methods. This study aimed to determine the short-term effect of KT and athletic tape (AT) on skin temperature in the lower back and explore the possible effect of different taping methods (Y-strip and fan-strip taping) on local microcirculation.

Materials And Methods: Twenty-six healthy participants completed the test-retest reliability measurement of the infrared thermography (IRT), intraclass correlation coefficient (ICC), and standard error of measurement (SEM) were calculated to evaluate the reliability. Then, 21 healthy participants received different taping condition randomly for 5 times, including Y-strip of kinesio taping (KY), fan-strip of kinesio taping (Kfan), Y-strip of athletic taping (AY), fan-strip of athletic taping (Afan), and no taping (NT). Above taping methods were applied to the participants' erector spinae muscles on the same side. Skin temperature of range of interest (ROI) was measured in the taping area through IRT at pre taping and 10 min after taping. Additionally, participants completed self-perceived temperature evaluation for different taping methods through visual analog scaling. One-way repeated-measured analysis of variance was used to compare the temperature difference among different taping methods. Bonferroni test was used for post hoc analysis.

Results: There was a good test-retest reliability (ICC = 0.82, 95% CI = 0.60-0.92; SEM = 0.33; and MD = 0.91) of the IRT. Significant differences were observed in the short-term effect on skin temperature among all different taping methods ( = 0.012, = 3.435, and η = 0.147), test showed a higher significantly skin temperature difference in Kfan taping compared to no taping ( = 0.026, 95% CI = 0.051-1.206); However, no significant differences were observed among self-perceived temperature ( = 0.055, = 2.428, and η = 0.108).

Conclusion: This study showed that the fan-strip of KT increased significantly the skin temperature of the waist after taping for 10 min. The application of KT may modify the skin temperature of the human body and promote local microcirculation, although it remained unclear for the real application.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7251151PMC
http://dx.doi.org/10.3389/fphys.2020.00488DOI Listing

Publication Analysis

Top Keywords

skin temperature
32
taping methods
28
taping
19
temperature
11
skin
9
methods
8
healthy participants
8
participants completed
8
test-retest reliability
8
kinesio taping
8

Similar Publications

The human skin maintains a comfortable and healthy somatosensory state by sensing different aspects of the thermal environment, including temperature value, heat source, energy level, and duration. However, state-of-the-art thermosensors only measure basic temperature values, not the full range of the thermosensation function of human skin. Here, we propose a heat source recognition () sensor of poly(butyl acrylate)-lithium bis(n-fluoroalkylsulfonyl)imide (PBA-Li:FSI;  = 1, 3, 5), which enables response to temperature, pressure, and proximity stimulus signals based on the relaxation behavior of the ionic gel and distinguished between different types of heat sources (i.

View Article and Find Full Text PDF

Thermal-Sensitive Artificial Ionic Skin with Environmental Stability and Self-Healing Property.

ACS Appl Mater Interfaces

January 2025

Key Laboratory of Organic Optoelectronics and Molecular Engineering and Laboratory of Flexible Electronics Technology, Department of Chemistry, Tsinghua University, Beijing 100084, P. R. China.

Wearable temperature-sensitive electronic skin enables robots to rapidly detect environmental changes and respond intelligently, thereby reducing temperature-related mechanical failures. Additionally, this temperature-sensitive skin can measure and record the temperature of external objects, broadening its potential applications in the medical field. In this study, we designed a thermally sensitive artificial ionic skin using ionic liquids (ILs) as solvents and carbon nanotubes (CNTs) as thermally conductive fillers.

View Article and Find Full Text PDF

Understanding Local Thermal Comfort and Physiological Responses in Older People Under Uniform Thermal Environments.

Physiol Behav

January 2025

School of Mechanical Engineering, Tongji University, Shanghai, China; Institute for Environmental Design and Engineering, University College London, UK.

The ageing population has increased the attention on care services for older people, particularly concerning their health and thermal comfort. However, most existing studies focus on the overall thermal comfort of older people, with insufficient research into their local thermal needs for different body parts, impeding precise thermal adjustments and optimal thermal satisfaction. This study investigated the local thermal comfort and skin temperature of older people under various environmental conditions.

View Article and Find Full Text PDF

Temperature regulation in dogs is significantly impaired during general anesthesia. Glabrous skin on paws may facilitate thermoregulation from this area and is a potential target for interventions attenuating hypothermia. This pilot study aimed to compare efficacy of an innovative warming device placed on the front paws (AVAcore; AVA), with no warming methods (NONE) and conventional truncal warming methods (CONV; circulating water blanket/forced air warmer) on rectal temperature and anesthetic recovery times.

View Article and Find Full Text PDF

Introduction: The initial 24-h period following admission to a hospital holds profound significance for pediatric patients, representing a critical window where proactive interventions can substantially influence outcomes. We devised a simple triage system, pediatric simple triage score (PSTS), to see whether rapid triage of sick pediatric patients with fever can be done using the new triage system in the emergency department (ED) to predict hospital admission.

Methods: This was a prospective observational study, conducted at the department of emergency medicine of a tertiary care teaching hospital in southern India.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!