Radiotherapy for the treatment of pituitary adenomas: A dosimetric comparison of three planning techniques.

Rep Pract Oncol Radiother

Department of Radiotherapy, Instituto Mexicano Del Seguro Social (IMSS), Centro Médico Nacional de Occidente, Universidad de Guadalajara, Independencia Oriente, Guadalajara 44340, Mexico.

Published: May 2020

Aim: Our goal was to compare conformal 3D (C3D) radiotherapy (RT), modulated intensity RT (IMRT), and volumetric modulated arc therapy (VMAT) planning techniques in treating pituitary adenomas.

Background: RT is important for managing pituitary adenomas. Treatment planning advances allow for higher radiation dosing with less risk of affecting organs at risk (OAR).

Materials And Methods: We conducted a 5-year retrospective review of patients with pituitary adenoma treated with external beam radiation therapy (C3D with flattening filter, flattening filter-free [FFF], IMRT, and VMAT). We compared dose-volume histogram data. For OARs, we recorded D2%, maximum, and mean doses. For planning target volume (PTV), we registered V95%, V107%, D95%, D98%, D50%, D2%, minimum dose, conformity index (CI), and homogeneity index (HI).

Results: Fifty-eight patients with pituitary adenoma were included. Target-volume coverage was acceptable for all techniques. The HI values were 0.06, IMRT; 0.07, VMAT; 0.08, C3D; and 0.09, C3D FFF (p < 0.0001). VMAT and IMRT provided the best target volume conformity (CI, 0.64 and 0.74, respectively; p < 0.0001). VMAT yielded the lowest doses to the optic pathway, lens, and cochlea. The position of the neck in extreme flexion showed that it helps in planning mainly with VMAT by allowing only one arc to be used and achieving the desired conformity, decreasing the treatment time, while allowing greater protection to the organs of risk using C3D, C3DFFF.

Conclusions: Our results confirmed that EBRT in pituitary adenomas using IMRT, VMAT, C3D, C3FFF provide adequate coverage to the target. VMAT with a single arc or incomplete arc had a better compliance with desired dosimetric goals, such as target coverage and normal structures dose constraints, as well as shorter treatment time. Neck extreme flexion may have benefits in treatment planning for better preservation of organs at risk. C3D with extreme neck flexion is an appropriate treatment option when other treatment techniques are not available.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7264003PMC
http://dx.doi.org/10.1016/j.rpor.2020.04.020DOI Listing

Publication Analysis

Top Keywords

pituitary adenomas
8
planning techniques
8
patients pituitary
8
pituitary adenoma
8
pituitary
5
radiotherapy treatment
4
treatment pituitary
4
adenomas dosimetric
4
dosimetric comparison
4
comparison three
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!