Background Context: Long thoracolumbar fixation and fusion have become a consolidated treatment for severe spinal disorders. Concomitant sacropelvic fixation with S2 alar-iliac (S2AI) screws is frequently performed to limit instrumentation failure and pseudarthrosis at the lumbosacral junction.

Purpose: This study explored the use of triangular titanium implants in different configurations in which the implants supplemented standard sacropelvic fixation with S2AI screws in order to further increase the stability of S2AI fixation.

Study Design: Finite element study.

Methods: Four T10-pelvis instrumented models were built: pedicle screws and rods in T10-S1 (PED); pedicle screws and rods in T10-S1, and bilateral S2 alar-iliac screws (S2AI); pedicle screws and rods in T10-S1, bilateral S2AI screws, and triangular implants inserted bilaterally in a sacral alar-iliac trajectory (Tri-SAI); pedicle screws and rods in T10-S1, bilateral S2AI screws and two bilateral triangular titanium implants inserted in a lateral trajectory (Tri-Lat). The models were tested under pure moments of 7.5 Nm in flexion-extension, lateral bending and axial rotation.

Results: SIJ motion was reduced by 50% to 66% after S2AI fixation; the addition of triangular titanium implants in either a SAI or a lateral trajectory further reduced it. S2AI, Tri-SAI, and Tri-Lat resulted in significantly lower stresses in S1 pedicle screws when compared to PED. Triangular implants had a protective effect on the maximal stresses in S2AI screws, especially when placed in the SAI trajectory. Sacropelvic fixation did not have any protective effect on the posterior rods.

Conclusions: Supplementing S2AI screws with triangular implants had a protective effect on the S2AI screws themselves, as well as the S1 pedicle screws, in the tested model.

Clinical Significance: Triangular implants can substantially reduce the residual flexibility of the SIJ with respect to S2AI fixation alone, suggesting a possible role in patients needing reinforced fixation. In vivo investigation is needed to determine if these in vitro effects translate into clinically important differences.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.spinee.2020.05.552DOI Listing

Publication Analysis

Top Keywords

s2ai screws
28
pedicle screws
24
triangular implants
20
sacropelvic fixation
16
screws rods
16
rods t10-s1
16
screws
14
s2ai
12
triangular titanium
12
titanium implants
12

Similar Publications

Triangular pelvic fixation in the management of adult spinal deformities: technical note and preliminary results.

Orthop Traumatol Surg Res

December 2024

Aix-Marseille Université, APHM, CNRS, ISM, CHU Timone, Service de Chirurgie Orthopédique et Vertébrale, 264 rue Saint-Pierre, 13005 Marseille, France. Electronic address:

Article Synopsis
  • The choice of the lower vertebra for spinal fixation in adult spinal deformity, particularly around the lumbosacral junction, is debated, with options including stopping fixation at S1 or using lower points like S2AI or iliac screws to prevent implant pullout.
  • A new technique for posterior fixation combines S1 screws, iliac screws, and sacro-iliac implants, inspired by triangular pelvic fixation methods used for trauma.
  • This study outlines the operative technique using fluoroscopic guidance and shares preliminary results from treating 15 patients, labeled as level IV evidence.
View Article and Find Full Text PDF

A Misplaced S2 Alar-Iliac Screw Causing L5 Spinal Nerve Injury: A Report of a Rare Case.

Cureus

November 2024

Orthopaedic Surgery and Sports Medicine, Tsukuba University Hospital Mito Clinical Education and Training Center, Mito Kyodo General Hospital, Mito, JPN.

Although neurovascular structures, including the superior gluteal artery, sciatic nerve, obturator nerve, internal iliac vein and artery, and lumbosacral plexus, are at risk when S2 alar-iliac (S2AI) screws are used, no cases of nerve injuries have been reported. An 84-year-old man was referred to our institute with persistent left sciatica for seven months after undergoing salvage surgery using S2AI screws for deep surgical site infection from a previous posterior interbody fusion surgery at L5-S1. Based on the radiographic and diagnostic selective nerve root block findings, a diagnosis of left L5 radiculopathy was suspected due to the left S2AI screw being caudally misplaced and severely protruding into the pelvic cavity.

View Article and Find Full Text PDF

Sacral/Pelvic Fixation: New Tools and Techniques.

Neurosurg Clin N Am

January 2025

Department of Neurosurgery, University of Arizona, 1501 N Campbell Avenue, Tucson, AZ 85724, USA. Electronic address:

This review article explores the advancements in sacropelvic fixation, comparing traditional and modern techniques, with a focus on iliac and sacral 2 alar-iliac screw fixations. It addresses the biomechanical challenges inherent in securing the lumbosacral junction and discusses the integration of current and future technologies like robotics and augmented reality to improve surgical outcomes. The article underscores the importance of these innovations in enhancing stability and reducing complications in complex spinal surgeries.

View Article and Find Full Text PDF

Purpose: This study sought to compare screw placement accuracy and outcomes between freehand (FH) and AR-guided pelvic fixation. While pelvic fixation is a critical technique in spinal deformity surgery, S2-alar iliac (S2AI) screw placement poses challenges.

Methods: We conducted a case-control study of 50 consecutive patients who underwent spinopelvic fixation at a single institution.

View Article and Find Full Text PDF

[Entry point and screw path study of second sacral alar-iliac screw trajectory in spinal pelvic fixation under O-arm navigation].

Zhonghua Yi Xue Za Zhi

November 2024

Division of Spine Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, the Affiliated Hospital of Medical School, Nanjing University, Nanjing 210008, China Division of Spine Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital Clinical College of Nanjing Medical University, Nanjing 210008, China.

To explore the feasibility of using the entry point and screw path parameters of sacroiliac (SAI) screws inserted under O-arm 3D computer navigation as a reference for freehand screw insertion in patients with degenerative spinal deformities. A retrospective analysis was conducted on the clinical data of 66 patients with degenerative spinal deformities who received SAI screw fixation assisted by the O-arm 3D computer navigation system at Nanjing Drum Tower Hospital Affiliated with Nanjing University Medical School from January 2017 to April 2022. The patients included 6 males and 60 females, with a mean age of (64.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!