Introduction: Hip fracture is a major cause of morbidity and mortality in older adults. Intertrochanteric hip fractures often are treated surgically using cephalomedullary nails (CMN), in either a short or long length. Their outcomes are documented in the literature; however, outcomes of the intermediate-length CMN have not been well described.
Methods: A retrospective review was conducted of older adults with intertrochanteric hip fractures that were treated with cephalomedullary nail fixation using an intermediate-length (235 mm Synthes Trochanteric Fixation nail or 240 mm Stryker Gamma 3) nail. Outcome data were collected during the inpatient stay and 16 months post-operatively.
Results: Seventy-seven patients met inclusion criteria and were reviewed during inpatient stay; however, only 42 had documented post-operative outcomes. Of those, two patients died post-discharge and were not included in the 16-month follow-up. Comparison of results to published literature suggested that intermediate-length nails are comparable to short-length nails with regard to time in the operating room and estimated blood loss. The rate of blood transfusion was lower and length of hospital stay was shorter than in comparable studies of both short- and long-length nails. There were no post-operative peri-prosthetic fractures in the 16-month follow-up. This rate was lower than published rates for short and long nails. The hardware failure rate (3/42, 7.1%) of intermediate-length nails was higher than comparison studies of both short- and long-length nails.
Conclusion: Patient outcomes for intermediate-length nails were similar to outcomes of shorter length nails. Utilization of the intermediate-length nail appears to be an effective treatment option for repair of intertrochanteric femur fractures. However, direct comparison is difficult since peri-prosthetic fracture rate may increase over time and nail length and hardware failure are not defined consistently in the literature. Further study is needed with a larger sample size followed over a longer period of time to confirm our findings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7266504 | PMC |
J Chem Theory Comput
October 2024
Department of Chemistry, Chicago Center for Theoretical Chemistry, James Franck Institute, and Institute for Biophysical Dynamics, The University of Chicago, Chicago, Illinois 60637, United States.
The Martini 3.0 coarse-grained force field, which was parametrized to better capture transferability in top-down coarse-grained models, is analyzed to assess its accuracy in representing thermodynamic and structural properties with respect to the underlying atomistic representation of the system. These results are compared to those obtained following the principles of statistical mechanics that start from the same underlying atomistic system.
View Article and Find Full Text PDFBackground: A sport-related concussion (SRC) is a common injury that affects multiple clinical domains such as cognition, balance, and nonspecific neurobehavioral symptoms. Although multidimensional clinical assessments of concussion are widely accepted, there remain limited empirical data on the nature and clinical utility of distinct clinical profiles identified by multimodal assessments.
Purpose: Our objectives were to (1) identify distinct clinical profiles discernible from acute postinjury scores on the Sport Concussion Assessment Tool (SCAT), composed of a symptom checklist, a cognitive assessment (Standardized Assessment of Concussion), and a balance assessment (Balance Error Scoring System), and (2) evaluate the clinical utility of the identified profiles by examining their association with injury characteristics, neuropsychological outcomes, and clinical management-related outcomes.
J Formos Med Assoc
June 2024
Department of Orthopaedics, University Medical Center Utrecht, Utrecht, Netherlands. Electronic address:
Aims: Managing proximal humerus pathologic fractures requires strategic planning to ensure optimal patient outcomes. Traditionally, fixation of the humerus using long devices has been considered the standard of care, but emerging evidence has challenged this approach. This study aimed to compare long plates (LPs) and intermediate-length plates (IPs) in this clinical context.
View Article and Find Full Text PDFInt J Mol Sci
June 2021
Department of Clinical and Experimental Sciences, University of Brescia, 25123 Brescia, Italy.
Introduction: Hip fracture is a major cause of morbidity and mortality in older adults. Intertrochanteric hip fractures often are treated surgically using cephalomedullary nails (CMN), in either a short or long length. Their outcomes are documented in the literature; however, outcomes of the intermediate-length CMN have not been well described.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!