Capillary electrophoretic separation of ketamine, norketamine, hydroxynorketamine, and dehydronorketamine was performed in the counter-current regime under the influence of oppositely-directed electroosmotic flow. For this purpose, the fused silica capillaries were covalently coated with the poly(acrylamide-co-3-acrylamidopropyl trimethylammonium chloride) copolymer (PAMAPTAC). The content of the cationic monomer APTAC in the polymerization mixture varied in the range 0-6 mol. % and the generated electroosmotic flow increased continuously in the 0-20 · 10 mVs interval. Importantly, it resulted in improved electrophoretic resolution of ketamine/norketamine, which increased from 0.8 for neutral PAM coating (i.e. 0% PAMAPTAC) to 3.0 for 6% PAMAPTAC. The determination of ketamine and its derivates in rat serum was performed in a 4% PAMAPTAC capillary with an inner diameter of 25 μm. The separation was performed in a 500 mM aqueous solution of acetic acid (pH 2.3). The clinical sample was deproteinized by the addition of acetonitrile to the serum and a large volume of the treated sample was injected directly into the capillary. The achieved limit of detection ranged from 2.2 ng/mL for dehydronorketamine to 4.1 ng/mL for hydroxynorketamine; the intra-day repeatability was 1.0-1.5% for the migration time and 2.8-3.3% for the peak area. The developed methodology was employed for time monitoring of ketamines in rat serum after intra venous administration of low doses of anaesthetic at a level of 2 μg per g of body weight.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2020.121094 | DOI Listing |
Langmuir
January 2025
School of Civil Engineering, Wuhan University, Wuhan 430072, China.
This study evaluates the feasibility of converting Ca-montmorillonite into Na-montmorillonite through electroosmosis. Comprehensive analyses of current, pH, ζ-potential, and ethylene glycol expansion were conducted to investigate the macro- and microscale effects of electroosmosis. The results demonstrate that electroosmosis effectively reduces the swelling properties of montmorillonite.
View Article and Find Full Text PDFTalanta
January 2025
DSM-Firmenich, Kogle Allé 4, 2970, Hørsholm, Denmark.
The development and validation of an accurate, selective, and eco-friendly capillary zone electrophoretic detection (CZE) method has been presented for concurrent measurement of inorganic and organic anions including chloride, sulfate, formic acid, citric acid, acetic acid, phosphate, and glutamic acid in Human Milk Oligosaccharides (HMOs) for the first time. An electrolyte composed of an aqueous solution of benzoic acid, 16.38 mM; l-histidine, 24.
View Article and Find Full Text PDFSoft Matter
January 2025
Department of Mathematics, National Institute of Technology Durgapur, Durgapur-713209, India.
The present article deals with the modulation of oscillatory electroosmotic flow (EOF) and solute dispersion across a nanochannel filled with an electrolyte solution surrounded by a layer of a dielectric liquid. The dielectric permittivity of the liquid layer adjacent to supporting rigid walls is taken to be lower than that of the electrolyte solution. Besides, the aforesaid liquid layer may bear additional mobile charges, , free lipid molecules, charged surfactant molecules , which in turn lead to a nonzero charge along the liquid-liquid interface.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, 066004, PR China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, PR China. Electronic address:
Background: Fractionation of microalgal cells has important applications in producing pharmaceuticals and treating diseases. Multiple types of microalgal cells generally coexist in the oceans or lakes and are easily contaminated by microplastics and bacteria. Therefore, it is of paramount significance to develop an effective fractionation approach for microalgal cells for biological applications.
View Article and Find Full Text PDFJ Phys Chem Lett
January 2025
School of Chemical Engineering and Light Industry, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
Efficient capture of single-stranded DNA (ssDNA) is crucial for high-throughput sequencing, which influences the speed and accuracy of genetic analysis. Electrophoresis (EP) and electro-osmotic flow (EOF) have a significant impact on the translocation behavior of ssDNA through the nanopore. Experimentally, dynamically tracking these two effects remains challenging, and conventional numerical methods also struggle to capture their dynamic properties in the presence of DNA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!