Objective: There has been an increase in the use of the CE-Chirp stimulus in automated auditory brainstem response (AABR) equipment for neonatal hearing screening. The purpose of this study is to evaluate the diagnostic accuracy of the LS CE-Chirp-evoked auditory brainstem response (ABR) compared to the click-evoked ABR for the identification of different degrees and configurations of sensorineural (SNHL) hearing loss.
Method: 49 ears with mild to moderate SNHL were assessed: 16 ears with rising SNHL and 33 ears with sloping high frequency SNHL. Behavioural pure tone thresholds were obtained at 125-8000 Hz and ABR thresholds were measured using the click and LS CE-Chirp stimuli respectively. Click- and LS CE-Chirp-evoked thresholds were compared with each other and with behavioural pure tone average at 500, 1000, 2000 Hz (PTA), high frequency average at 2000, 4000, 8000 Hz (HFA) and low frequency average at 250, 500, 1000 Hz (LFA). Diagnostic accuracy of the two ABR stimuli was also compared by using ROC curves.
Results: Differences between click- and LS CE Chirp-evoked ABR, and behavioural thresholds were not statistically significant (p > 0.05). The highest significant correlations for ABR using clicks to behavioural thresholds was found at 2000 and 4000 Hz, whereas, the highest correlation for LS CE-Chirp ABRs to behavioural thresholds was found at 1000, 2000 and 4000 Hz (r > 0.7, p < 0.001). A very strong, positive correlation was found between both click (r = 0.805, p < 0.001) and LS CE-Chirp (r = 0.825, p < 0.001) and the behavioural PTA. LS CE-Chirp ABR thresholds were closer to mid and low frequency thresholds than the click ABR while the click-evoked thresholds were in closer proximity to HFA. Sensitivity and specificity and false negative rates were identical. Diagnostic accuracy of the LS CE-Chirp ABR was equal to or better than click for low (area under the curve (AUC) = 0.83), mid (AUC = 0.89) and high frequency hearing losses (AUC = 0.73). However, scatterplots indicated more frequent underestimation of behavioural pure tone thresholds at mid and high frequencies with the LS CE-Chirp than for the click ABR.
Conclusion: The diagnostic accuracy of the LS CE Chirp-evoked ABR is equivalent or better than the click-evoked ABR. The importance of ongoing surveillance and consideration of ABR screening protocols is consequently emphasized.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijporl.2020.110071 | DOI Listing |
Eur J Radiol
January 2025
Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:
Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.
View Article and Find Full Text PDFEur J Radiol
January 2025
Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:
Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.
Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.
Am Fam Physician
January 2025
Martin Army Community Hospital, Fort Moore, Georgia.
Dysuria, a feeling of pain or discomfort during urination, is often caused by urinary tract infection but can also be due to sexually transmitted infection, bladder irritants, skin lesions, and some chronic pain conditions. History is most often useful for finding signs of sexually transmitted infection, complicated infections, lower urinary symptoms in males, and noninfectious causes. Most patients presenting with dysuria should have a urinalysis performed.
View Article and Find Full Text PDFJCO Precis Oncol
January 2025
Translational Research Support Office, National Cancer Center Hospital East, Chiba, Japan.
Purpose: Human epidermal growth factor receptor 2 (HER2)-targeted therapies have shown promise in treating -amplified metastatic colorectal cancer (mCRC). Identifying optimal biomarkers for treatment decisions remains challenging. This study explores the potential of artificial intelligence (AI) in predicting treatment responses to trastuzumab plus pertuzumab (TP) in patients with -amplified mCRC from the phase II TRIUMPH trial.
View Article and Find Full Text PDFInvest Radiol
January 2025
From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).
Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!