What Is Known And Objective: We investigated the elimination efficiency and pharmacokinetics (PK) parameters of vancomycin (VCM) in patients undergoing continuous haemodiafiltration (CHDF) using a polyethyleneimine-coated polyacrylonitrile membrane (AN69ST) for dosage adjustment.
Methods: We conducted a retrospective study of CHDF patients treated with VCM from December 2017 to August 2019. We calculated PK parameters of VCM and determined the 24-hour dose required to maintain the target trough concentration of VCM (VCM ).
Results And Discussion: The average (95% CI) volume of distribution and total clearance of VCM were 75.5 L (63.7-87.3 L) and 1.84 L/h (1.38-2.30 L/h), respectively, and the elimination rate constant and half-life were 0.026/h (0.017-0.034/h) and 31.2 h (22.8-39.5 h), respectively. The average AN69ST clearance of VCM (CL ) was 0.69 L/h (0.52-0.86 L/h). The estimated average doses required to maintain VCM of 10, 15 and 20 μg/mL were 623.1 mg (379.8-866.4 mg), 934.6 mg (569.7-1299.5 mg) and 1246.2 mg (759.6-1732.8 mg), respectively.
What Is New And Conclusion: The PK of VCM and CL of AN69ST were clarified. These results suggest that it is possible to adjust the dose of VCM in using AN69ST, which efficiently removes cytokines, and contributes to improvement of serious infections.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jcpt.13197 | DOI Listing |
Talanta
January 2025
Translational Glycomics Research Group, Research Institute of Biomolecular and Chemical Engineering, University of Pannonia, Veszprem, Hungary; Horváth Csaba Memorial Laboratory of Bioseparation Sciences, Research Center for Molecular Medicine, Faculty of Medicine, University of Debrecen, Hungary. Electronic address:
Sodium dodecyl sulfate capillary gel electrophoresis (SDS-CGE) is a frequently used analytical technique in size-based separation of proteins, playing a vital role in the biopharmaceutical industry for the analysis and characterization of therapeutic proteins, employing both UV and fluorescent detection. Understanding the effect of the operational parameters using easily applicable in migratio fluorescent labeling is increasingly critical, especially because multicapillary electrophoresis systems with fluorescent detection have recently gained prominence in high-throughput biopolymer analysis. In this study, the effects of the three most important user-adjustable operational parameters (temperature, gel concentration, and electric field strength) were investigated on the electrophoretic mobility and resolution of SDS-protein complexes in the presence of propidium iodide in the gel-buffer system.
View Article and Find Full Text PDFUnlabelled: The purpose of this study was to translate and validate a questionnaire to be used by children with chronic diseases during procedures. Specific research questions were as follows: Is the translated versions reliable? Is there a correlation between VCM and another questionnaire measuring discomfort to enhance the validity of VCM? The three versions of Visual CARE measure (VCM) were translated following the principles of good practice for translation and cultural adaptation of patient-reported outcome measures, according to the International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Cognitive debriefing interviews with children, parents, and healthcare professionals were carried out.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Division of Biotechnologies, Italian National Agency for Energy, New Technologies and Sustainable Economic Development (ENEA), 00123 Rome, Italy.
In the tissue regeneration field, stem cell transplantation represents a promising therapeutic strategy. To favor their implantation, proliferation and differentiation need to be controlled. Several studies have demonstrated that stem cell fate can be controlled by applying continuous electric field stimulation.
View Article and Find Full Text PDFBiomed Eng Lett
January 2025
Power Electronics Research Centre, School of Engineering, University of Galway, Galway, Ireland.
Purpose: Pulsed electrical field (PEF) ablation is an energy-based technique used to treat a range of cancers by irreversible electroporation (IRE). Our objective was to use computational and plant-based models to characterize the electric field distribution and ablation zones induced with a commercial 8-needle array-based applicator intended for treatment of skin cancer when high-frequency IRE (H-FIRE) pulses are applied. Electric field characterisation of this device was not previously assessed.
View Article and Find Full Text PDFJ Avian Med Surg
January 2025
Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA 70803, USA.
Viscoelastic testing evaluates the formation and lysis of a clot over time, allowing more complete assessment of patient hemostasis in real time, whereas traditional tests, such as prothrombin time and partial thromboplastin time, only measure coagulation factor function. Patient-side viscoelastic coagulation monitors are easy to use, portable, and provide faster turnaround time than commercial laboratories. Viscoelastic testing requires only 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!