  • The study investigates the effects of high kVp techniques on radiographic image quality in digital systems, suggesting that these methods can reduce radiation doses without compromising image quality.
  • The research involved analyzing pelvis and lumbar spine radiographs from a hospital archive, using a visual grading rubric to assess image quality across different kVp settings.
  • Results showed significant dose reduction with higher kVp while maintaining comparable image quality scores, validating the high kVp technique as effective for minimizing patient radiation exposure.

Article Abstract

Introduction: High kVp techniques, 15% or 10-kVp rules, are well-known dose reduction methods. Traditionally, the use of high tube potential (i.e. increased kVp) is associated with decreased radiographic contrast and overall image quality. Recent studies suggest contrast and image quality are not heavily reliant on kVp with digital systems. This study aims to assess the effects of the high tube potential technique on clinical radiographic image quality when using digital systems, to validate high kVp as a dose saving technique.

Methods: A selection of comparable pelvis and lumbar spine radiographs were collected from the hospital's picture archiving and communication system (PACS), with technical factors recorded. All clinical radiographs were assessed by 5 senior radiographers using a 15-point visual grading analysis (VGA) rubric.

Results: For 40 AP pelvis radiographs and 40 lateral lumbar spine radiographs, reduction in the dose area product (DAP) with higher kVp is seen. Average pelvis DAP at 75 kVp = 14.06 mGy.cm ; 85 kVp = 7.47 mGy.cm . Average lumbar spine DAP at 80 kVp = 15.76 mGy.cm ; 90 kVp = 14.83 mGy.cm . Image quality and contrast scores showed no statistically significant difference between the high and low kVp groups (z = 0.06 and 0.12, respectively). Average pelvis VGA score at 75 kVp = 11.26; 85 kVp = 12.55. Average lumbar spine VGA score at 80 kVp = 9.23; 90 kVp = 10.64.

Conclusions: The high tube potential techniques allowed for reduced patient radiation doses whilst showing no degradation of diagnostic image quality in a clinical setting. This study successfully validates the high kVp technique as a useful tool for reducing patient radiation doses whilst maintaining high diagnostic image quality for digital pelvis and lumbar spine radiography.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7753839PMC
http://dx.doi.org/10.1002/jmrs.403DOI Listing

Publication Analysis

Top Keywords

image quality
28
lumbar spine
24
tube potential
16
pelvis lumbar
12
spine radiographs
12
high kvp
12
high tube
12
high
8
contrast image
8
digital systems
8

Similar Publications

Adherence to institutional stroke alert criteria in an academic adult emergency department population.

Clin Neurol Neurosurg

December 2024

Department of Emergency Medicine, Vanderbilt University Medical Center, Nashville, TN, USA; Geriatric Research, Education, and Clinical Center, Tennessee Valley Healthcare Center, Nashville, TN, USA; Department of Biomedical Informatics, Vanderbilt University Medical Center, Nashville, TN, USA. Electronic address:

Background: Timely recognition of acute ischemic stroke (AIS) is essential to identify patients who may be eligible for acute intervention. Protocols to streamline systems-based care, such as "stroke alerts" in the emergency department (ED) can safely reduce time-to-care while enhancing safety. However, clinician adherence to stroke alert criteria is poorly described.

View Article and Find Full Text PDF

Background: Knee injuries resulting in purely cartilaginous defects are rare, and controversy remains regarding the reliability of chondral-only fixation.

Purpose: To systematically review the literature for fixation methods and outcomes after primary fixation of chondral-only defects within the knee.

Study Design: Systematic review; Level of evidence, 5.

View Article and Find Full Text PDF

Optimized methods for scRNA-seq and snRNA-seq of skeletal muscle stored in nucleic acid stabilizing preservative.

Commun Biol

January 2025

Center for Research on Genomics and Global Health, National Human Genome Research Institute, National Institutes of Health, Bethesda, MD, 20892, USA.

Single cell studies have transformed our understanding of cellular heterogeneity in disease but the need for fresh starting material can be an obstacle, especially in the context of international multicenter studies and archived tissue. We developed a protocol to obtain high-quality cells and nuclei from dissected human skeletal muscle archived in the preservative Allprotect® Tissue Reagent. After fluorescent imaging microscopy confirmed intact nuclei, we performed four protocol variations that compared sequencing metrics between cells and nuclei enriched by either filtering or flow cytometry sorting.

View Article and Find Full Text PDF

Objectives: The objective of this web-based study is to analyze the attributes of bariatric surgery cases ensuing health implications. Additionally, the study seeks to delve into the factors influencing post-bariatric psychological evaluations and the impact of various bariatric surgeries on weight loss and psycho-social assessment scores for patients who had undergone bariatric surgeries within a specific bariatric surgery center in Egypt between January 2017 and January 2024.

Methods: An analytical cross-sectional study recruited 411 adults who had undergone different bariatric procedures by the same surgical team.

View Article and Find Full Text PDF

Background: Bilateral risk-reducing mastectomies (RRMs) have been proven to decrease the risk of breast cancer in patients at high risk owing to family history or having pathogenic genetic mutations. However, few resources with consolidated data have detailed the patient experience following surgery. This systematic review features patient-reported outcomes for patients with no breast cancer history in the year after their bilateral RRM.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!