We examine the influence of steady shear on structural relaxation in a simulated coarse-grained unentangled polymer melt over a wide range of temperature and shear rates. Shear is found to progressively suppress the α-relaxation process observed in the intermediate scattering function, leading ultimately to a purely inertially dominated β-relaxation at high shear rates, a trend similar to increasing temperature. On the basis of a scaling argument emphasizing dynamic heterogeneity in cooled liquids and its alteration under material deformation, we deduce and validate a parameter-free scaling relation for both the structural relaxation time τ from the intermediate scattering function and the "stretching exponent" β quantifying the extent of dynamic heterogeneity over the entire range of temperatures and shear rates that we can simulate.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7182423 | PMC |
http://dx.doi.org/10.1126/sciadv.aaz0777 | DOI Listing |
Int Endod J
January 2025
School of Medicine and Dentistry, Griffith University, Gold Coast, Australia.
Introduction: Biofilms may show varying adherence strengths to dentine. This study quantified the shear force required for the detachment of multispecies biofilm from the dentine using fluid dynamic gauging (FDG) and computation fluid dynamics (CFD). To date this force has not been quantified.
View Article and Find Full Text PDFVet Med (Praha)
November 2024
Department of Veterinary Surgery, College of Veterinary Medicine, Jeonbuk National University, Republic of Korea.
This study aimed to measure the whole blood viscosity (WBV) in racehorses using a new viscometer and establish reference values, as well as to investigate the correlation between the WBV and the haematological parameters and serum chemistry. WBV measurements were conducted on 51 Thoroughbred horses using a novel U-shaped scanning capillary-tube viscometer. The reference values for the WBV were determined at various shear rates ranging from 1 s to 1 000 s.
View Article and Find Full Text PDFUltrasound Med Biol
January 2025
Echosens, Paris, France.
Objective: Although FibroScan (FS), based on Vibration-Controlled Transient Elastography (VCTE), is a widely used non-invasive device for assessing liver fibrosis and steatosis, its current standard-VCTE examination remains timely and difficult on patients with obesity. The Guided-VCTE examination uses continuous shear waves to locate the liver by providing a real-time predictive indicator for shear wave propagation and uses shear wave maps averaging to increase the signal-to-noise ratio in difficult to assess patients. We aimed to evaluate the effectiveness of the new indicator, as well as compare examination times and success rates with both standard-VCTE and Guided-VCTE examinations.
View Article and Find Full Text PDFSpine (Phila Pa 1976)
January 2025
Indiana Spine Group Location of investigation Indiana Spine Group, 13225 N. Meridian Street, Carmel, IN 46032.
Study Design: Retrospective cohort.
Objective: To compare the clinical outcomes of trial versus standard clinical practice (SCP) patients following cervical disc arthroplasty (CDA).
Background: CDA is hypothesized to reduce the shear strain and related complications resulting from fusion procedures.
J Fluid Mech
December 2024
Université de Technologie de Compiègne, CNRS, Biomechanics and Bioengineering, Compiégne, France.
Capsules, which are potentially-active fluid droplets enclosed in a thin elastic membrane, experience large deformations when placed in suspension. The induced fluid-structure interaction stresses can potentially lead to rupture of the capsule membrane. While numerous experimental studies have focused on the rheological behavior of capsules until rupture, there remains a gap in understanding the evolution of their mechanical properties and the underlying mechanisms of damage and breakup under flow.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!