A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

6X acuros algorithm validation in the presence of inhomogeneities for VMAT treatment planning. | LitMetric

6X acuros algorithm validation in the presence of inhomogeneities for VMAT treatment planning.

Rep Pract Oncol Radiother

St.Luke's Hospital, Highfield Rd, Rathfarnham, Dublin 6, Ireland.

Published: April 2020

Aim: To validate the Acuros®XB (AXB) dose calculation algorithm for a 6 MV beam from the Varian TrueBeam treatment units.

Background: Currently Anisotropic Analytic Algorithm (AAA) is clinically used on authors' department but AXB could replace it for VMAT treatments in regions where inhomogeneities and free air are present.

Materials And Methods: Two steps are followed in the validation process of a new dose calculation algorithm. The first is to check the accuracy of algorithm for a homogenous phantom and regular fields. Multiple fields of increasing complexity have been acquired using a Mapcheck diode array. The accuracy of the algorithm was evaluated using the gamma analysis method. The second is to validate the algorithm in the presence of heterogeneous media. Planar absolute dose was measured with GafChromic®EBT2 film and was compared with the dose calculated by AXB. Gamma analysis was performed between Mapcheck measurements and AXB dose calculations, at a range of clinical source-surface distance.

Results: For SSDs ranging from 80 to 100 cm, the results show a minimum pass rate of 95% between AXB and Mapcheck acquisition. For open 6 MV photon beam interacting with a phantom with an air gap, the agreement after the air gap between AXB and GafChromic®EBT2 is less than 1% in the 3 × 3cm field and less than 2% in the 10 × 10 cm field.

Conclusions: AXB has advanced modelling of lateral electron transport that enables a more accurate dose calculation in heterogeneous regions and, compared with AAA, improves accuracy between different density interfaces. This will be of particular benefit for head/neck treatments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7256059PMC
http://dx.doi.org/10.1016/j.rpor.2020.03.018DOI Listing

Publication Analysis

Top Keywords

dose calculation
12
axb dose
8
calculation algorithm
8
accuracy algorithm
8
gamma analysis
8
air gap
8
axb
7
dose
6
algorithm
6
acuros algorithm
4