Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Breast cancer survivors (BCS) are often characterized by decreased pressure pain thresholds (PPT), range of motion (ROM) and strength in and around the shoulder affected by the treatment. This intra-rater reliability study was to establish the relative and absolute reliability of PPT's, active ROM and maximal isokinetic muscle strength (MIMS) of the affected shoulder in BCS with persistent pain after treatment.
Methods: Twenty-one BCS participated in the study. The PPTs of 17 locations and pain intensity were assessed using a pressure algometer and a numeric rating scale. The ROM was measured using a universal goniometer and MIMS was measured using an isokinetic dynamometer. Relative reliability was estimated using intra class correlation coefficient (ICC), and absolute reliability using standard error of measurement (SEM). Minimum detectable change (MDC) was calculated from SEM.
Results: The ICCs for PPTs ranged from 0.88-0.97, with SEM values ranging from 12.0 to 28.2 kPa and MDC ranging from 33.2 to 78.2 kPa. The ICCs for ROM ranged from 0.66-0.97, with SEM values ranging from 3.0 to 7.5° and MDC ranging from 8.4 to 20.8°. Finally, ICCs for MIMS ranged from 0.62-0.92, with SEM values ranging from 0.03 to 0.07 Nm/Kg FFM and MDC ranging from 0.09 to 0.19 Nm/kg FFM.
Conclusion: The results of this study indicate that PPTs, ROM and MIMS can be measured reliably on the affected shoulder in BCS with pain after treatment. This offer the possibility of using these measures to assess the effectiveness of interventions in this population.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7269234 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0234118 | PLOS |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!