Introduction: There are many papers in the available literature on the pre-operative evaluation of malignant melanoma (MM) using a 20 MHz probe. In many Western European countries, this examination is standard in the diagnosis of such lesions in terms of the resection margin. However, few papers describe and compare the results of melanoma thickness measurements using 20 and 50 MHz frequency probes.

Aim: The aim of the study was to evaluate the thickness of melanoma using 20 and 50 MHz probes. In addition, the obtained values were evaluated in comparison to the thickness values obtained in the histopathological examination.

Material And Methods: Melanoma malignum was confirmed histopathologically in 19 out of 72 patients. Then only those 19 patients were enrolled in the study.

Results: A correlation was demonstrated between the thickness of the melanoma measured with the 20 and 50 MHz probes, expressed in mm, and the thickness obtained in the histopathological examination expressed in millimeters (Breslow's scale). It was 0.759 ( < 0.001) and 0.734 ( < 0.001), respectively. The average thickness of melanomas obtained in ultrasound examination was identical for both probes and was 0.74 mm.

Conclusions: It seems that both types of probes can be used to assess melanoma thickness. The demonstrated correlation of high-frequency ultrasonography (HFUS) thickness with Breslow's scale indicates that the HFUS evaluation can be used in determination of melanoma resection margins as a repeatable, painless, non-invasive test.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7262812PMC
http://dx.doi.org/10.5114/ada.2018.79939DOI Listing

Publication Analysis

Top Keywords

high-frequency ultrasonography
8
pre-operative evaluation
8
melanoma
8
melanoma mhz
8
thickness
8
melanoma thickness
8
thickness melanoma
8
mhz probes
8
breslow's scale
8
evaluation
4

Similar Publications

Background: Aging associated with the passage of time causes alterations in subcutaneous tissues and the overall appearance of the skin that generate aesthetic unconformities in people. Within the wide range of available techniques on the market, radiofrequency (RF) diathermy has emerged as one of the most used non-invasive methods to combat them.

Objective: This clinical trial aims to determine and quantify the effectiveness and safety of the high-frequency RF-based device Symmed (Termosalud Inc.

View Article and Find Full Text PDF

Physiological responses derived from audiovisual perception during assisted driving are associated with the regulation of the autonomic nervous system (ANS), especially in emergencies. However, the interaction of event-related brain activity and the ANS regulating peripheral physiological indicators (i.e.

View Article and Find Full Text PDF

Fluid Distribution: Response to Intermittent Pneumatic Compression in People With and Without Primary Lymphedema.

Lymphat Res Biol

January 2025

Caring Futures Institute, College of Nursing and Health Sciences, Flinders University, Bedford Park, Australia.

Current understanding of changes in fluid distribution in response to the application of compression in primary lymphedema (PLE) is limited. This study measured fluid distribution before and after one application of standardized intermittent pneumatic compression (IPC) in the lower limbs of people with PLE, compared with those without lymphedema. High-frequency ultrasound (HFU) was used to measure dermal fluid, bioimpedance to measure segmental fluid, and percent water content (PWC) to measure fluid at specific anatomical points.

View Article and Find Full Text PDF

Background: Lung ultrasound (LUS) is increasingly utilized in veterinary medicine to assess pulmonary conditions. However, the characterization of pleural line and subpleural fields using different ultrasound transducers, specifically high-frequency linear ultrasound transducers (HFLUT) and curvilinear transducers (CUT), remains underexplored in canine patients. This study aimed to evaluate inter-rater agreement in the characterization of pleural line and subpleural fields using B- and M-mode ultrasonography in dogs with and without respiratory distress.

View Article and Find Full Text PDF

Ultra-high-frequency Ultrasound in the Objective Assessment of Chlormethine Gel Efficacy: A Case Report.

Acta Dermatovenerol Croat

November 2024

Agata Janowska, MD, Department of Dermatology, , University of Pisa, Via Roma 67, 56126, Pisa, Italy; Phone: +39 050 992436, Fax: +39 050 992556,

Mycosis fungoides (MF) represent the most frequent form of cutaneous T-cell lymphoma (CTCL). Chlormethine gel has been approved as first-line therapy in MF. The classification of early forms of MF is clinically and histologically complex even for experienced clinicians.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!