A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Immediate aspiration of the drug infused via central venous catheter through the distally positioned central venous dialysis catheter: An experimental study. | LitMetric

Objectives: The aim of this study was to construct an experimental model replicating blood flow within human superior vena cava and to determine the degree of the immediate aspiration of the drug introduced via central venous catheter through the distally positioned dialysis catheter.

Methods: A model replicating superior vena cava was built, catheters were inserted into the model, placing the orifice of the central venous catheter in positions regarding the orifice of the arterial lumen in central venous dialysis catheter (from +2 to -8 cm). Methylene blue was used as a tracer, and the concentration was determined by ultraviolet-visible spectroscopy. Four different sets of samples were generated according to infusion and aspiration speeds: continuous-slow, continuous-fast, bolus-slow, and bolus-fast.

Results: The concentration of the tracer was related to the distance between the catheter tips, representing a bimodal dependence. When the central venous catheter was placed distally to the central venous dialysis catheter, the aspiration of the tracer was minimal. When withdrawing the central venous catheter proximally, the aspiration of the tracer increased, reaching its peak at -4 cm with aspiration rates form 4.2% to 140.7%. Furthermore, the infusion speed of the tracer had more effect on the aspirated concentrations than the aspiration speed.

Conclusion: Findings of our experimental model suggest that concentration of aspired drug is effected by the distance between the central venous catheter and central venous dialysis catheter, being lowest when the drug is infused distally to central venous dialysis catheter. Furthermore, the concentration of the tracer is directly proportional to the infusion speed and far less effected by the aspiration rate of the drug.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1129729820924555DOI Listing

Publication Analysis

Top Keywords

central venous
44
venous catheter
24
venous dialysis
20
dialysis catheter
20
catheter
12
catheter distally
12
central
11
venous
11
aspiration
8
aspiration drug
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!