Solenoid actuated driver valve for high repetition rate shock tubes.

Rev Sci Instrum

Chemical Sciences and Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave., Lemont, Illinois 60439, USA.

Published: May 2020

A high speed, high pressure solenoid actuated valve has been developed for use as a driver section for automated shock tubes. The valve is based on a prior design, and significant improvements in the design of the valve are described. The new design retains the performance of prior versions of the valve and creates very reproducible reaction conditions in the shock tube, which are illustrated by several thousand experiments. In addition, the longevity of the valve is improved, failures are reduced, and the maintenance and manufacture of the valve are simplified.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0006010DOI Listing

Publication Analysis

Top Keywords

solenoid actuated
8
shock tubes
8
valve
7
actuated driver
4
driver valve
4
valve high
4
high repetition
4
repetition rate
4
rate shock
4
tubes high
4

Similar Publications

This study introduces an innovative in situ lander/impact-penetrator design tailored for Discovery-class missions to Europa, specifically focused on conducting astrobiological analyses. The platform integrates a microfluidic capacitively coupled contactless conductivity detector (C4D), optimized for the detection of low-concentration salts potentially indicative of biological activity. Our microfluidic system allows for automated sample routing and precise conductivity-based detection, making it suitable for the harsh environmental and logistical demands of Europa's icy surface.

View Article and Find Full Text PDF

Rigid solenoid coils have long been indispensable in modern intelligent devices. However, their sparse structure and challenging preparation of flexible coils for soft robots impose limitations. Here, a transformable 3D curved high-density liquid metal coil (HD-LMC) is introduced that surpasses the structural density level of enameled wire.

View Article and Find Full Text PDF

Size and shape control of microgel-encapsulating tumor spheroid via a user-friendly solenoid valve-based sorter and its application on precise drug testing.

Biosens Bioelectron

November 2024

Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, 518057, China; Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon, Hong Kong SAR, China; Key Laboratory of Biochip Technology, Biotech and Health Centre, Shenzhen Research Institute of City University of Hong Kong, Shenzhen, China. Electronic address:

The precision of previous cancer research based on tumor spheroids, especially the microgel-encapsulating tumor spheroids, was limited by the high heterogeneity in the tumor spheroid size and shape. Here, we reported a user-friendly solenoid valve-based sorter to reduce this heterogeneity. The artificial intelligence algorithm was employed to detect and segmentate the tumor spheroids in real-time for the size and shape calculation.

View Article and Find Full Text PDF

In optical experiments, shutters are devices that open or close a path of light. They are often used to limit the duration of light exposure onto a target or onto a detector to reduce possible light-induced damage. Many commercial shutters are available for different applications - some provide very fast opening and closing times, some can handle large optical powers, and others allow for fail-safe operation.

View Article and Find Full Text PDF

Achieving near-zero particle generation by simplicity of design-A compliant-mechanism-based gripper for clean-room environments.

SLAS Technol

August 2024

Leibniz Universität Hannover, Institute of Mechantronic Systems, An der Universität 1, Garbsen 30823, Lower Saxony, Germany.

Lab Automation facilitates high-throughput processes and improves reproducibility and efficiency while removing human action, primary source of contaminating particles. Handling poses a risk of contamination due to close contact with the objects. We propose a novel gripper (CrocoGrip) relying on compliant mechanisms to reduce the amount of contaminating particles generated by the gripper rather than preventing their emission, the latter being the common approach in current grippers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?