A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The impact of a high-quality basic life support police-based first responder system on outcome after out-of-hospital cardiac arrest. | LitMetric

Background: Laypersons' efforts to initiate basic life support (BLS) in witnessed Out-of-Hospital Cardiac Arrest (OHCA) remain comparably low within western society. Therefore, in order to shorten no-flow times in cardiac arrest, several police-based first responder systems equipped with automated external defibrillators (Pol-AED) were established in urban areas, which subsequently allow early BLS and AED administration by police officers. However, data on the quality of BLS and AED use in such a system and its impact on patient outcome remain scarce and inconclusive.

Methods: A total of 85 Pol-AED cases were randomly assigned to a gender, age and first rhythm matched non-Pol-AED control group (n = 170) in a 1:2 ratio. Data on quality of BLS were extracted via trans-thoracic impedance tracings of used AED devices.

Results: Comparing Pol-AED cases and the control group, we observed a similar compression rate per minute (p = 0.677) and compression ratio (p = 0.651), mirroring an overall high quality of BLS administered by police officers. Time to the first shock was significantly shorter in Pol-AED cases (6 minutes [IQR: 2-10] vs. 12 minutes [IQR: 8-17]; p<0.001). While Pol-AED was not associated with increased sustained return of spontaneous circulation (p = 0.564), a strong and independent impact on survival until hospital discharge (adj. OR: 1.85 [95%CI: 1.06-3.23; p = 0.030]) and a borderline significance for the association with favorable neurological outcome (adj. OR: 1.58 [95%CI: 0.96-2.89; p = 0.052) were observed.

Conclusion: We were able to demonstrate an early start and a high quality of BLS and AED use in Pol-AED assessed OHCA cases. Moreover, the presence of Pol-AED care was associated with better patient survival and borderline significance for favorable neurological outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7266310PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0233966PLOS

Publication Analysis

Top Keywords

cardiac arrest
12
quality bls
12
pol-aed cases
12
basic life
8
life support
8
police-based responder
8
out-of-hospital cardiac
8
bls aed
8
police officers
8
data quality
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!