A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of Personal Protective Equipment on Pediatric Cardiopulmonary Resuscitation Performance: A Controlled Trial. | LitMetric

Objectives: This study aimed to determine whether personal protective equipment (PPE) results in deterioration in chest compression (CC) quality and greater fatigue for administering health care providers (HCPs).

Methods: In this multicenter study, HCPs completed 2 sessions. In session 1 (baseline), HCPs wore normal attire; in session 2, HCPs donned full PPE. During each session, they performed 5 minutes of uninterrupted CCs on a child manikin. Chest compression rate, depth, and release velocity were reported in ten 30-second epochs. Change in CC parameters and self-reported fatigue were measured between the start and 2- and 5-minute epochs.

Results: We enrolled 108 HCPs (prehospital and in-hospital providers). The median CC rate did not change significantly between epochs 1 and 10 during baseline sessions. Median CC depth and release velocity decreased for 5 minutes with PPE. There were no significant differences in CC parameters between baseline and PPE sessions in any provider group. Median fatigue scores during baseline sessions were 2 (at start), 4 (at 2 minutes), and 6 (at 5 minutes). There was a significantly higher median fatigue score between 0 and 5 minutes in both study sessions and in all groups. Fatigue scores were significantly higher for providers wearing PPE compared with baseline specifically among prehospital providers.

Conclusions: During a clinically appropriate 2-minute period, neither CC quality nor self-reported fatigue worsened to a significant degree in providers wearing PPE. Our data suggest that Pediatric Basic Life Support recommendations for CC providers to switch every 2 minutes need not be altered with PPE use.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7274141PMC
http://dx.doi.org/10.1097/PEC.0000000000002109DOI Listing

Publication Analysis

Top Keywords

personal protective
8
protective equipment
8
chest compression
8
depth release
8
release velocity
8
self-reported fatigue
8
baseline sessions
8
median fatigue
8
fatigue scores
8
providers wearing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!