Development of an Accurate Resonant Frequency Controlled Wire Ultrasound Surgical Instrument.

Sensors (Basel)

Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, 350-27 Gumi-daero, Gumi 39253, Korea.

Published: May 2020

Our developed wire ultrasound surgical instrument comprises a bolt-clamped Langevin ultrasonic transducer (BLUT) fabricated by PMN-PZT single crystal material due to high mechanical quality factor and electromechanical coupling coefficient, a waveguide in the handheld instrument, and a generator instrument. To ensure high performance of wire ultrasound surgical instruments, the BLUT should vibrate at an accurate frequency because the BLUT's frequency influences hemostasis and the effects of incisions on blood vessels and tissues. Therefore, we implemented a BLUT with a waveguide in the handheld instrument using a developed assembly jig process with impedance and network analyzers that can accurately control the compression force using a digital torque wrench. A generator instrument having a main control circuit with a low error rate, that is, an output frequency error rate within ±0.5% and an output voltage error rate within ±1.6%, was developed to generate the accurate frequency of the BLUT in the handheld instrument. In addition, a matching circuit between the BLUT and generator instrument with a network analyzer was developed to transfer displacement vibration efficiently from the handheld instrument to the end of the waveguide. Using the matching circuit, the measured S-parameter value of the generator instrument using a network analyzer was -24.3 dB at the resonant frequency. Thus, our proposed scheme can improve the vibration amplitude and accuracy of frequency control of the wire ultrasound surgical instrument due to developed PMN-PZT material and assembly jig process.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7309115PMC
http://dx.doi.org/10.3390/s20113059DOI Listing

Publication Analysis

Top Keywords

wire ultrasound
16
ultrasound surgical
16
handheld instrument
16
generator instrument
16
surgical instrument
12
instrument developed
12
error rate
12
instrument
11
resonant frequency
8
waveguide handheld
8

Similar Publications

Background: Cementless hip hemiarthroplasty is one of the options for the treatment of osteoporotic femoral neck fractures. Intraoperative periprosthetic femoral calcar fractures sometimes occur during the surgery, and the use of cerclage wiring to maintain the position and stability of the femoral stem and prevent the progression of the fracture. This study examines the outcomes of cerclage wiring to treat intraoperative periprosthetic calcar fractures in cementless hip hemiarthroplasty in osteoporotic femoral neck fractures.

View Article and Find Full Text PDF

[Comparison of effectiveness between two surgical methods for humeral lateral condyle fractures in children].

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi

January 2025

Department of Orthopedics, Anhui Provincial Children's Hospital, Anhui Medical University Children's Medical Center, Hefei Anhui, 230051, P. R. China.

Objective: To compare the effectiveness of ultrasound-guided closed reduction with Kirschner wire fixation and open reduction with Kirschner wire fixation in the treatment of humeral lateral condyle fracture (HLCF) in children.

Methods: A clinical data of 53 children with HLCF admitted between May 2020 and April 2023 and met selective criteria was retrospectively analyzed. Of these, 25 cases were managed with closed reduction and Kirschner wire fixation under ultrasound guidance (closed group), while 28 cases underwent open reduction and Kirschner wire fixation (open group).

View Article and Find Full Text PDF

Background: Most breast cancers are detected at an early stage in which case conservative surgery is indicated. An accurate preoperative localization technique is essential for conservative surgery of non-palpable breast lesions. Currently, the gold standard technique is wire localization (WL).

View Article and Find Full Text PDF

Background: Intraoperative ultrasound-guided breast-conserving surgery guarantees real-time direct visualization of tumor and resection margins. We compared surgical, oncologic, and cosmetic outcomes between intraoperative ultrasound-guided breast-conserving surgery and traditional (palpation- or wire-guided) surgery across all breast cancer lesion types.

Methods: This prospective observational cohort study was conducted at the Veneto Institute of Oncology between January 2021 and October 2022.

View Article and Find Full Text PDF

Transcatheter Aspiration of Tricuspid Vegetation.

JACC Case Rep

December 2024

Jesselson Integrated Heart Center, The Eisenberg R&D Authority, Shaare Zedek Medical Center, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem, Israel.

Objective: This study sought to present the endovascular approach of transcatheter aspiration using the FlowTriever (Inari Medical) aspiration system for high surgical risk patients with right-sided infective endocarditis.

Key Steps: General anesthesia and transesophageal echocardiogram guidance; ultrasonography-guided femoral vein access, preclosure sutures, and insertion of a 24-F sheath; insertion of straight 24-F aspiration cannula over a stiff wire, parked in the superior vena cava; introduction of a 20-F curved cannula inside the 24-F cannula to create a telescopic assembly; accurate positioning using the right ventricle inflow/outflow projection in biplane mode; adjustment of the curved cannula radius by sliding the inner cannula in and out inside the mother cannula; manual aspiration of the vegetation; Postaspiration transesophageal echocardiogram assessment.

Potential Pitfalls: Avoid leaflet and annular injury and account for potential embolization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!