Background: Recent studies have shown that fluoroquinolones, specifically, enrofloxacin and its active metabolite (ciprofloxacin), cross the equine placenta without causing gross or histological lesions in the first and third trimester fetuses or resulting foal. However, it is possible that in utero exposure to fluoroquinolones may cause subtle lesions not detectable by standard means; thus, a more in-depth assessment of potential toxicity is warranted.

Objectives: To use quantitative magnetic resonance imaging (qMRI), biomechanical testing, and chondrocyte gene expression to evaluate the limbs of foals exposed to enrofloxacin during the third trimester of pregnancy.

Study Design: In vivo and control terminal experiment.

Methods: Healthy mares at 280 days gestation were assigned into three groups: untreated (n = 5), recommended therapeutic (7.5 mg/kg enrofloxacin, PO, SID, n = 6) or supratherapeutic (15 mg/kg, PO, SID, n = 6) doses for 14 days. Mares carried and delivered to term and nursed their foals for ~30 days. Two additional healthy foals born from untreated mares were treated post-natally with enrofloxacin (10 mg/kg PO, SID, for 5 days). By 30 days, foal stifles, hocks, elbows, and shoulders were radiographed, foals were subjected to euthanasia, and foal limbs were analysed by quantitative MRI, structural MRI, biomechanical testing and chondrocyte gene expression.

Results: Osteochondral lesions were detected with both radiography and structural MRI in foals from both enrofloxacin-treated and untreated mares. Severe cartilage erosions, synovitis and joint capsular thickening were identified in foals treated with enrofloxacin post-natally. Median cartilage T2 relaxation times differed between joints but did not differ between treatment groups.

Main Limitations: A small sample size was assessed and there was no long-term follow-up.

Conclusion: While further research is needed to address long-term foal outcomes, no differences were seen in advanced imaging, biomechanical testing or gene expression by 30 days of age, suggesting that enrofloxacin may be a safe and useful antibiotic for select bacterial infections in pregnant mares.

Download full-text PDF

Source
http://dx.doi.org/10.1111/evj.13295DOI Listing

Publication Analysis

Top Keywords

biomechanical testing
12
third trimester
8
testing chondrocyte
8
chondrocyte gene
8
gene expression
8
sid n = 6
8
untreated mares
8
structural mri
8
foals
7
enrofloxacin
6

Similar Publications

Vacuum-assisted delivery (VAD) uses a vacuum cup on the fetal scalp to apply traction during uterine contractions, assisting complicated vaginal deliveries. Despite its widespread use, VAD presents a higher risk of neonatal morbidity compared to natural vaginal delivery and biomechanical evidence for safe VAD traction forces is still limited. The aim of this study is to develop and assess the feasibility of an experimental VAD testing setup, and investigate the impact of traction forces on fetal brain deformation.

View Article and Find Full Text PDF

Robust multi-modal fusion architecture for medical data with knowledge distillation.

Comput Methods Programs Biomed

December 2024

School of Biomedical Engineering, Capital Medical University, No.10, Xitoutiao, You An Men, Fengtai District, Beijing 100069, China; Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, No.10, Xitoutiao, You An Men, Fengtai District, Beijing 100069, China. Electronic address:

Background: The fusion of multi-modal data has been shown to significantly enhance the performance of deep learning models, particularly on medical data. However, missing modalities are common in medical data due to patient specificity, which poses a substantial challenge to the application of these models.

Objective: This study aimed to develop a novel and efficient multi-modal fusion framework for medical datasets that maintains consistent performance, even in the absence of one or more modalities.

View Article and Find Full Text PDF

Background: There is inconsistent evidence suggesting that people with chronic low back pain may differ in variability of repeated trunk movements compared to people without chronic low back pain. These inconsistencies may be due to low reliability and task dependence of movement variability measures, which can be addressed using multiple movement tasks and summary measures.

Methods: Participants with and without chronic low back pain were recruited.

View Article and Find Full Text PDF

Background: Cementoplasty has been successfully used for treating fractures in various parts of the human body, although the use in weight-bearing long bones is a subject of controversial debate. Strategies to improve the mechanical properties of polymethylmethacrylate-based bone cement (BC) comprise changing the chemical composition or the application of metal reinforcement strategies. In clinical practice reinforced bone cement is used despite biomechanical basic research regarding this topic being scare.

View Article and Find Full Text PDF

Objectives: The aim of this study was to compare the effectiveness of different attachment shapes and locations on the extrusion of the upper left lateral incisor (UL2) using thermoplastic aligners.

Materials And Methods: Seven typodonts were digitally printed with hemi-ellipsoid or rectangular attachments in the incisal, middle or cervical third of the UL2. Five clear aligners were fabricated for each typodont; each was tested twice.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!