Purpose: In retrospective clinical studies digital variance angiography (DVA) provided higher contrast-to-noise ratio and better image quality than digital subtraction angiography (DSA). Our aim was to verify the clinical usefulness and benefits of DVA in carbon dioxide (CO)-assisted lower limb interventions.
Materials And Methods: A workstation running the DVA software was integrated into a Siemens Artis Zee with Pure angiography system, and this new image processing technology was used in four patients (3 male, 1 female, age: 76.2 ± 4.2 years) with peripheral artery disease (PAD, Rutherford 2-3) and impaired renal function (average eGFR 25.5 ± 11.2 ml/min/1.73 m). The DSA and DVA images of 46 CO-assisted runs were visually evaluated by five experts in single-image evaluation using a 5-grade Likert scale and in paired comparisons.
Results: DVA images received significantly higher score (3.84 ± 0.10) than DSA images (3.31 ± 0.10, p < 0.001). Raters preferred DVA images in terms of diagnostic value and usefulness for therapeutic decisions in 85.2% and 83.9% of all comparisons, respectively. These benefits were achieved at lower frame rates (1-3 FPS) than usually recommended for CO angiography (4-6 FPS). No adverse events were recorded during or after the procedures.
Conclusions: Our initial experience shows that DVA might facilitate the correct diagnostic and therapeutic decisions, and potentially help to reduce radiation exposure in lower limb CO angiography. Although the dose management capabilities of DVA have to be validated in further clinical studies, this technology might be a useful new tool in the operating room and contributes to the safety and efficacy of CO-enhanced endovascular interventions.
Level Of Evidence: Level IV.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7369257 | PMC |
http://dx.doi.org/10.1007/s00270-020-02530-5 | DOI Listing |
EClinicalMedicine
October 2024
Toronto 3D Knowledge Synthesis and Clinical Trials Unit, Clinical Nutrition and Risk Factor Modification Center, St. Michael's Hospital, Unity Health Toronto, Toronto, ON M5B 1W8, Canada.
Background: Use of health applications (apps) to support healthy lifestyles has intensified. Different app features may support effectiveness, including gamification defined as the use of game elements in a non-game situation. Whether health apps with gamification can impact behaviour change and cardiometabolic risk factors remains unknown.
View Article and Find Full Text PDFJ Prosthodont Res
January 2025
Department of Stomatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Purpose: This retrospective cohort study evaluated the accuracy of analog versus virtual wax-ups in prosthetic-driven planning and guided surgery.
Methods: There were 73 patients with a single missing posterior tooth who underwent either an analog or virtual wax-up design following a prosthetic-driven concept. Intraoral scans of the final restoration were performed 1 year after completion of the restoration.
J Prosthodont Res
January 2025
Department of Prosthetic Dentistry, Medical University of Innsbruck, Innsbruck, Austria.
Purpose: To determine the effect of wall thickness on the fracture load of hollow-structured zirconia teeth fabricated using 3D printing.
Methods: The geometry of an artificial ceramic tooth (mandibular right first molar) was copied and modified. The final test group design yielded wall thicknesses of 0.
J Dent
January 2025
Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland;; Department of Prosthetic Dentistry and Material Science, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Objective: To compare the in vitro scan accuracy (trueness and precision) of recently introduced wireless intraoral scanners (IOSs) to commonly used wired IOSs in different fixed partial denture (FPD) situations.
Methods: Three partially edentulous maxillary models with implants located at different sites (lateral incisors [Model 1]; right canine and first molar [Model 2]; right first premolar and first molar [Model 3]) were digitized with wireless (Primescan 2 [P2] and TRIOS 5 [T5]) and wired (Primescan [P1] and TRIOS 3 [T3]) IOSs (n=14 per IOS-model pair). The models were also digitized with an industrial-grade optical scanner for their reference scans.
Int J Comput Assist Radiol Surg
January 2025
Department of Medical Biophysics, University of Toronto, Toronto, Canada.
Purpose: During endovascular revascularization interventions for peripheral arterial disease, the standard modality of X-ray fluoroscopy (XRF) used for image guidance is limited in visualizing distal segments of infrapopliteal vessels. To enhance visualization of arteries, an image registration technique was developed to align pre-acquired computed tomography (CT) angiography images and to create fusion images highlighting arteries of interest.
Methods: X-ray image metadata capturing the position of the X-ray gantry initializes a multiscale iterative optimization process, which uses a local-variance masked normalized cross-correlation loss to rigidly align a digitally reconstructed radiograph (DRR) of the CT dataset with the target X-ray, using the edges of the fibula and tibia as the basis for alignment.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!