Automation Advances in Stereoelectroencephalography Planning.

Neurosurg Clin N Am

Department of Clinical and Experimental Epilepsy, University College London, London, UK; National Hospital for Neurology and Neurosurgery, Queen Square, London, UK; Chalfont Centre for Epilepsy.

Published: July 2020

The past decade has seen a significant shift in the number of centers performing intracranial electroencephalography from subdural grids and strips to stereoelectroencephalography (SEEG). Unlike grid and strip insertion or other stereotactic procedures in which the cortical surface is visualized, SEEG involves insertion of an electrode through a bolt anchored into the skull. Due to the multidisciplinary nature of SEEG trajectory planning, it often is time-consuming and iterative. Computer-assisted planning improves time taken and efficacy of SEEG trajectory planning. This article provides an overview of the considerations, controversies, and practicalities of implementing an automated computer-assisted planning solution for SEEG planning.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7902942PMC
http://dx.doi.org/10.1016/j.nec.2020.03.005DOI Listing

Publication Analysis

Top Keywords

seeg trajectory
8
trajectory planning
8
computer-assisted planning
8
planning
6
seeg
5
automation advances
4
advances stereoelectroencephalography
4
stereoelectroencephalography planning
4
planning decade
4
decade shift
4

Similar Publications

Refining computer-assisted SEEG planning with spatial priors - A novel comparison of implantation strategies across adult and paediatric centres.

Neurophysiol Clin

January 2025

Developmental Neurosciences, UCL Great Ormond Street Institute of Child Health, London, WC1N 1EH, UK; Department of Neurosurgery, Great Ormond Street Hospital for Children, London, WC1N 3JH, UK.

Objectives: Computer-assisted planning (CAP) allows faster SEEG planning and improves grey matter sampling, orthogonal drilling angles to the skull, reduces risk scores and minimises intracerebral electrode length. Incorporating prior SEEG trajectories enhances CAP planning, refining output with centre-specific practices. This study significantly expands on the previous work, compares priors libraries between two centres, and describes differences between SEEG in adults and children in these centres.

View Article and Find Full Text PDF

Background: Stereoelectroencephalography (SEEG) is a common diagnostic surgical procedure for patients with medically refractory epilepsy. We aimed to describe our initial experience with the recently released NeuroOne Evo SEEG electrode product (Zimmer Biomet, Warsaw, IN) and review technical specifications for other currently approved depth SEEG electrodes.

Methods: We performed a record review on the first five patients implanted with NeuroOne Evo SEEG electrode product using the robotic stereotactic assistance robot platform and described our surgical technique in detail.

View Article and Find Full Text PDF

Background: Stereoelectroencephalography (SEEG), as a minimally invasive method that can stably collect intracranial electroencephalographic information over long periods, has increasingly been applied in the diagnosis and treatment of intractable epilepsy in recent years. Over the past 20 years, with the advancement of materials science and computer science, the application scenarios of SEEG have greatly expanded. Bibliometrics, as a method of scientifically analyzing published literature, can summarize the evolutionary process in the SEEG field and offer insights into its future development prospects.

View Article and Find Full Text PDF

Background: We assessed the accuracy and performed a directional analysis of robot-assisted implantation of stereoelectroencephalography (SEEG) depth electrodes in children using the frameless neurolocate 3D registration module.

Methods: Thirteen children with epilepsy undergoing stereotactic robot-assisted insertion of SEEG electrodes were included. Six children were operated on with standard frame-based registration while 7 with the use of the frameless neurolocate registration module.

View Article and Find Full Text PDF

Multiple intracerebral hematomas during SEEG recording and intradural hemorrhage after spinal tap: A case report prompting more research on collagen IV gene mutation and oral nicotine consumption as risk factors.

Epilepsia Open

November 2024

Department of Neurology, Neurocritical Care, and Neurorehabilitation, Center for Cognitive Neuroscience, European Reference Network EpiCARE, Christian Doppler University Hospital, Paracelsus Medical University, Salzburg, Austria.

Article Synopsis
  • - A 20-year-old man with drug-resistant epilepsy developed multiple intracerebral hemorrhages after receiving stereo-EEG electrodes and experiencing a lumbar spinal tap, with a history of heavy use of nicotine pouches.
  • - Genetic testing revealed a mutation in the COL4A2 gene, which is linked to collagen production and has previously been associated with hemorrhage risks, raising concerns about its role in the patient's complication.
  • - The study suggests that the combination of the COL4A2 mutation and high nicotine use could significantly increase the likelihood of bleeding during neurosurgical procedures, calling for more research into this connection.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!