Aims: Femoral revision component subsidence has been identified as predicting early failure in revision hip surgery. This comparative cohort study assessed the potential risk factors of subsidence in two commonly used femoral implant designs.

Methods: A comparative cohort study was undertaken, analyzing a consecutive series of patients following revision total hip arthroplasties using either a tapered-modular (TM) fluted titanium or a porous-coated cylindrical modular (PCM) titanium femoral component, between April 2006 and May 2018. Clinical and radiological assessment was compared for both treatment cohorts. Risk factors for subsidence were assessed and compared.

Results: In total, 65 TM and 35 PCM cases were included. At mean follow-up of seven years (1 to 13), subsidence was noted in both cohorts during the initial three months postoperatively (p < 0.001) then implants stabilized. Subsidence noted in 58.7% (38/65 cases) of the TM cohort (mean 2.3 mm, SD 3.5 mm) compared to 48.8% (17/35) of PCM cohort (mean 1.9 mm, SD 2.6 mm; p = 0.344). Subsidence of PCM cohort were significantly associated with extended trochanteric osteotomy (ETO) (p < 0.041). Although the ETO was used less frequently in PCM stem cohort (7/35), subsidence was noted in 85% (6/7) of them. Significant improvement of the final mean Oxford Hip Score (OHS) was reported in both treatment groups (p < 0.001).

Conclusion: Both modular TM and PCM revision femoral components subsided within the femur. TM implants subsided more frequently than PCM components if the femur was intact but with no difference in clinical outcomes. However, if an ETO is performed then a PCM component will subside significantly more and suggests the use of a TM implant may be advisable. Cite this article: 2020;102-B(6):709-715.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.102B6.BJJ-2019-1366.R2DOI Listing

Publication Analysis

Top Keywords

femoral revision
8
subsidence
8
comparative cohort
8
cohort study
8
risk factors
8
factors subsidence
8
pcm
8
modular pcm
8
pcm cohort
8
frequently pcm
8

Similar Publications

Background: To analyze the effects of the positioning of a bolt in the femoral neck system (FNS) on the short-term outcomes of middle-aged and young adults with displaced femoral neck fractures (FNFs).

Methods: This was a retrospective study involving 114 middle-aged and young adults with displaced FNFs who were surgically treated with internal fixation via the FNS in the Department of Orthopedics, Suzhou Municipal Hospital, from December 2019 to January 2023. The degree of deviation of the central axis of the femoral head and neck from the tip of the bolt (W), the tip‒apex distance (TAD) and the length of femoral neck shortening (LFNS) were measured on postoperative X-ray and computed tomography (CT) scan images.

View Article and Find Full Text PDF

Omniflow prosthesis for treatment prosthetic graft infection of the aorto-iliac and femoropopliteal level on the infrarenal aortic segment and lower extremity.

Ann Vasc Surg

January 2025

Department of for Cardiovascular Surgery, University Heart Centre Freiburg - Bad Krozingen, University Medical Centre Freiburg, Freiburg, Germany; Faculty of Medicine, Albert Ludwigs University Freiburg, Freiburg, Germany.

Objectives: To report outcomes after the use of the Omniflow II biosynthetic graft (LeMaitre Vascular, Il, USA) for vascular reconstruction in patients with prosthetic infection at the aorto-iliac and femoropopliteal level.

Methods: Within a six-year period, all consecutive patients with aorto-iliac and femoro-popliteal graft infection treated by resection of the infected graft material, extensive local debridement and reconstruction using Omniflow II biosynthetic graft were retrospectively analzyed. Patient characteristics, intraoperative details, postoperative outcomes, and infection details were assessed.

View Article and Find Full Text PDF

Surveillance of Dual-Mobility Hip Systems: Damage Mode and Clinical Data Analysis.

J Arthroplasty

January 2025

Oakland University William Beaumont School of Medicine, Rochester, MI; Department of Orthopedic Surgery, Corewell Health William Beaumont University Hospital, Royal Oak, MI. Electronic address:

Background: Hip instability following total hip arthroplasty (THA) is among the most common indications for revision surgery. The implantation of dual-mobility (DM) systems, designed to improve stability, continues to rise, and thus, characterizing in vivo implant damage modes is paramount.

Methods: Under an implant retrieval protocol, 51 DM THA systems were analyzed.

View Article and Find Full Text PDF

Cup-Cage Reconstruction for Pelvic Discontinuity: Encouraging Long-Term Survival.

J Arthroplasty

January 2025

Department of Orthopaedic Surgery, Division of Lower Limb Reconstruction, University of British Columbia, Vancouver, British Columbia, Canada.

Background: Pelvic discontinuity (PD) poses a difficult challenge in revision total hip arthroplasty (rTHA). There is a paucity of evidence assessing five- to ten-year outcomes of cup cages for PD. This study aimed to review the survivorship and outcomes of cup-cage constructs for PD.

View Article and Find Full Text PDF

The effect of bone relaxation on the simulated pull-off force of a cementless femoral knee implant.

J Biomech

January 2025

Radboudumc, Orthopaedic Research Lab, PO Box 9101, 6500 HB Nijmegen, the Netherlands.

Aseptic loosening is the primary cause of revision in cementless total knee arthroplasty (TKA), emphasizing the importance of strong initial stability for long-term implant success. Pre-clinical evaluations are crucial for understanding implant fixation mechanics and improving implant designs. Finite element (FE) analysis models often use linear elastic bone material models, which do not accurately reflect bone's mechanical behavior.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!