A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Temperature-guided ablation with the second-generation cryoballoon for paroxysmal atrial fibrillation: 3-year follow-up in a multicenter experience. | LitMetric

Purpose: A strategy based on the attainment of the specific parameter of - 40 °C within the first 60 s during cryoenergy applications in the setting of cryoballoon ablation (CB-A) without the use of an inner lumen mapping catheter (ILMC) (Achieve; Medtronic, USA) for the visualization of real-time recordings (RTR) has been previously described. The latter has proven to be very effective in guaranteeing freedom from atrial arrhythmias in patients affected by paroxysmal atrial fibrillation (PAF) at 1-year follow-up. The purpose of this retrospective observational study was to evaluate the clinical outcomes of this strategy in a multicenter experience on a long-term follow-up of 3 years.

Methods: A total of 192 patients having undergone CB ablation for paroxysmal AF (PAF) starting from September 2015 to November 2016 that underwent a temperature-guided approach were included.

Results: Mean procedural time was 68.77 ± 18.88. The mean number of freezes in the LSPV was 1.2 ± 0.4, 1.2 ± 0.4 in the LIPV, 1.1 ± 0.4 in the RSPV, and 1.2 ± 0.4 in the RIPV. Considering a blanking period of 3 months, freedom from AF off-AAD was achieved in 77.6% (149/192) at mean 34.5 ± 5.5 months and median 35.1 months (IQR, 32.3-37.0 months) follow-up after 1 procedure.

Conclusions: A temperature-guided approach affords freedom from AF at a 3-year follow-up period in a large majority of patients affected by PAF having undergone a single CB-A procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-020-00770-6DOI Listing

Publication Analysis

Top Keywords

paroxysmal atrial
8
atrial fibrillation
8
3-year follow-up
8
multicenter experience
8
temperature-guided approach
8
follow-up
5
temperature-guided ablation
4
ablation second-generation
4
second-generation cryoballoon
4
cryoballoon paroxysmal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!