Raman spectroscopy has long been considered a gold standard for optically based chemical identification, but has not been adopted in non-laboratory operational settings due to limited sensitivity and slow acquisition times. Ultraviolet (UV) Raman spectroscopy has the potential to address these challenges through the reduction of fluorescence from background materials and increased Raman scattering due to the shorter wavelength (relative to visible or near-infrared excitation) and resonant enhancement effects. However, the benefits of UV Raman must be evaluated against specific operational situations: the actual realized fluorescence reduction and Raman enhancement depend on the specific target materials, target morphology, and operational constraints. In this paper, the wavelength trade-space in UV Raman spectroscopy is evaluated for one specific application: checkpoint screening for trace explosive residues. The optimal UV wavelength is evaluated at 244, 266, and 355 nm for realistic trace explosive and explosive-related compound (ERC) residues on common checkpoint materials: we perform semi-empirical analysis that includes the UV penetration depth of common explosive and ERCs, realistic explosive and ERC residue particle sizes, and the fluorescence signal of common checkpoint materials. We find that while generally lower UV wavelength provides superior performance, the benefits may be significantly reduced depending on the specific explosive and substrate. Further, logistical requirements (size, weight, power, and cost) likely limit the adoption of optimal wavelengths. Graphical abstract.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-020-02725-2DOI Listing

Publication Analysis

Top Keywords

raman spectroscopy
16
trace explosive
12
ultraviolet raman
8
checkpoint screening
8
evaluated specific
8
common checkpoint
8
checkpoint materials
8
raman
7
explosive
6
optimization ultraviolet
4

Similar Publications

The utilization of single crystals is exponentially growing in optoelectronic devices due to their exceptional benefits, including high phase purity and the absence of grain boundaries. However, achieving single crystals with a porous structure poses significant challenges. In this study, we present a method for fabricating porous single crystals (porous-SC) of CsAgBiBr and related halide double perovskites using an infrared-assisted spin coating technique.

View Article and Find Full Text PDF

An ultrafast algorithm for ultrafast time-resolved coherent Raman spectroscopy.

Commun Chem

January 2025

Energy & Materials Transition, Netherlands Organization for Applied Scientific Research (TNO), Urmonderbaan 22, Geleen, 6167RD, The Netherlands.

Time-resolved coherent Raman spectroscopy (CRS) is a powerful non-linear optical technique for quantitative, in-situ analysis of chemically reacting flows, offering unparalleled accuracy and exceptional spatiotemporal resolution. Its application to large polyatomic molecules, crucial for understanding reaction dynamics, has thus far been limited by the complexity of their rotational-vibrational Raman spectra. Progress in developing comprehensive spectral codes for these molecules, a longstanding goal, has been hindered by prohibitively long computation times required for their spectral synthesis.

View Article and Find Full Text PDF

Prostate cancer is a disease which poses an interesting clinical question: Should it be treated? Only a small subset of prostate cancers are aggressive and require removal and treatment to prevent metastatic spread. However, conventional diagnostics remain challenged to risk-stratify such patients; hence, new methods of approach to biomolecularly sub-classify the disease are needed. Here we use an unsupervised self-organising map approach to analyse live-cell Raman spectroscopy data obtained from prostate cell-lines; our aim is to exemplify this method to sub-stratify, at the single-cell-level, the cancer disease state using high-dimensional datasets with minimal preprocessing.

View Article and Find Full Text PDF

This study used Raman and near-infrared (NIR) spectroscopy to monitor small real-time changes in powder blends and tablets in low-dose pharmaceutical formulations. The research aims to enhance process analytical technology (PAT) in pharmaceutical manufacturing, ensuring high-quality and uniform products with applications to produce drugs with narrow therapeutic indices (NTI). The study utilizes Raman and NIR spatially resolved spectroscopy (SRS) techniques to monitor a moderate cohesive material's active pharmaceutical ingredient (API) concentrations during manufacturing.

View Article and Find Full Text PDF

The accumulation of disposable face masks (DFMs) has become a significant threat to the environment due to extensive use during the COVID-19 pandemic. In this research, we investigated the degradation of DFMs after their disposal in landfills. We replicated the potential degradation process of DFMs, including exposure to sunlight before subjecting them to synthetic landfill leachate (LL).

View Article and Find Full Text PDF