Background: The incidence of hemodialysis (HD)-dependent renal failure after total artificial heart (TAH) implantation is high. We sought to determine the preoperative predictors of HD after TAH implantation.

Methods And Results: We studied 87 patients after TAH implantation at our institution between April 2006 and March 2017. Baseline clinical data were obtained from the medical records, and patients were followed until death or heart transplantation. We performed logistic regression analysis to identify predictors of HD after TAH implantation. Of the patients, 24 (28%) required postimplantation HD. Those requiring HD were more likely to have histories of coronary artery disease (58% vs 29%; P = 0.01), required preoperative membrane oxygenation (33% vs 4.8%; P = 0.001) and had lower baseline estimated glomerular filtration rates (54 ± 29 vs 67 ± 24 mL/min/1.73m; P = 0.04). Patients requiring HD were at a higher risk of death on device at 1 year (33% vs 5%, P = 0.001; log rank test: P =0.001, hazard ratio 6.6 [95% CI:1.8-23], P = 0.003).

Conclusions: The incidence of postimplantation HD is high and is associated with increased likelihood of mortality. Lower baseline estimated glomerular filtration rates, histories of coronary artery disease and preoperative membrane oxygenation support are predictors of postimplantation requirement of HD. These data may help to identify patients at risk for adverse outcomes after TAH implantation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cardfail.2020.05.011DOI Listing

Publication Analysis

Top Keywords

tah implantation
16
renal failure
8
total artificial
8
artificial heart
8
predictors tah
8
histories coronary
8
coronary artery
8
artery disease
8
preoperative membrane
8
membrane oxygenation
8

Similar Publications

Background: With an increasing number of Fontan patients surviving into adulthood, the burden of end-stage heart failure is increasing. Prior studies have reported suboptimal heart transplantation (HTx) outcomes. Therefore, the authors describe their institutional experience of HTx in patients with Fontan circulation failure, including heart-liver transplantation (HLTx) and pretransplant systemic ventricular assist device (SVAD) therapies.

View Article and Find Full Text PDF

Objective: The need for safe and reliable mechanical circulatory support (MCS) for smaller children with severe heart failure (HF) is well defined. More specifically, in pediatric patients with advanced congenital HF, there is no implantable total artificial heart (TAH) device available for small patients. Herein, we report the development of the infant continuous-flow total artificial heart (I-CFTAH), a fully implantable in infants and newborns.

View Article and Find Full Text PDF

Background: Durable biventricular support may be necessary to bridge patients with end-stage biventricular failure to heart transplantation. This study compares waitlist and post-transplant outcomes between patients supported with continuous flow, durable biventricular assist devices (BiVAD), and total artificial heart (TAH).

Methods: Using the UNOS registry, we analyzed adult (≥18 years old), first-time transplant candidates with TAH or BiVAD at the time of listing or transplantation from 10/1/2010-10/31/2020, with follow-up through 3/31/2022.

View Article and Find Full Text PDF

Background: ShuttlePump is a novel total artificial heart (TAH) recently introduced to potentially overcome the limitations associated with the current state-of-the-art mechanical circulatory support devices intended for adults. In this study, we adapted the outflow cannulation of the previously established ShuttlePump TAH and evaluated the anatomical compatibility using the virtual implantation technique.

Methods: We retrospectively assessed the anatomical compatibility of the ShuttlePump using virtual implantation techniques within 3D-reconstructed anatomies of adult heart failure patients.

View Article and Find Full Text PDF

Outcomes after SynCardia® temporary total artificial heart implantation: A 20-year single-center experience in 196 patients.

Artif Organs

February 2025

Department of Thoracic and Cardiovascular Surgery, Heart and Diabetes Center North Rhine-Westphalia, Ruhr University of Bochum, Bad Oeynhausen, Germany.

Background: The SynCardia® temporary total artificial heart (TAH) serves as a mechanical circulatory support device for patients suffering from irreversible biventricular failure.

Methods: This retrospective study analyzed 196 consecutive patients who underwent TAH implantation at our center from 2001 to 2021. We assessed survival rates and all-cause mortality during TAH support, including survival post-heart transplantation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?