Dynamic Buckling of an Elastic Ring in a Soap Film.

Phys Rev Lett

Mathematical Institute, University of Oxford, Woodstock Road, Oxford, OX2 6GG, United Kingdom.

Published: May 2020

Dynamic buckling may occur when a load is rapidly applied to, or removed from, an elastic object at rest. In contrast to its static counterpart, dynamic buckling offers a wide range of accessible patterns depending on the parameters of the system and the dynamics of the load. To study these effects, we consider experimentally the dynamics of an elastic ring in a soap film when part of the film is suddenly removed. The resulting change in tension applied to the ring creates a range of interesting patterns that cannot be easily accessed in static experiments. Depending on the aspect ratio of the ring's cross section, high-mode buckling patterns are found in the plane of the remaining soap film or out of the plane. Paradoxically, while inertia is required to observe these nontrivial modes, the selected pattern does not depend on inertia itself. The evolution of this pattern beyond the initial instability is studied experimentally and explained through theoretical arguments linking dynamics to pattern selection and mode growth. We also explore the influence of dynamic loading and show numerically that, by imposing a rate of loading that competes with the growth rate of instability, the observed pattern can be selected and controlled.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.124.198003DOI Listing

Publication Analysis

Top Keywords

dynamic buckling
12
soap film
12
elastic ring
8
ring soap
8
dynamic
4
buckling elastic
4
film
4
film dynamic
4
buckling occur
4
occur load
4

Similar Publications

Controlling the stability of monodisperse phospholipid-coated microbubbles by tuning their buckling pressure.

J Colloid Interface Sci

January 2025

BIOS/Lab on a Chip Group, Max Planck Center Twente for Complex Fluid Dynamics, MESA+ Institute for Nanotechnology, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, P.O. Box 217, Enschede, 7500 AE, the Netherlands. Electronic address:

Hypothesis: Monodisperse phospholipid-coated microbubbles, with a size and resonance frequency tuned to the ultrasound driving frequency, have strong potential to enhance sensitivity, efficiency, and control in emerging diagnostic and therapeutic applications involving bubbles and ultrasound. A key requirement is that they retain their gas volume and shell material during physiologic pressure changes and withstand the overpressure during intravenous injection. The shell typically comprises a mixture of a phospholipid (e.

View Article and Find Full Text PDF

This study investigates the quasi-static and dynamic compression performance of a newly designed stacked pyramidal lattice (SPL) structure composed of struts that resemble I-beams. These novel lattice structures are 3D-printed considering three different stacking sequences, and their stiffness, strength, and energy absorption properties are experimentally assessed through low-velocity impact (1.54 m/s) and quasi-static compression tests.

View Article and Find Full Text PDF

Review of femoroacetabular impingement syndrome.

J Hip Preserv Surg

December 2024

Hip and Knee Adult Reconstruction Department, Instituto Nacional de Rehabilitación Luis Guillermo Ibarra, Calzada México-Xochimilco No. 289 Colonia Arenal de Guadalupe Delegación, Tlalpan C.P., Ciudad de México 14389, México.

Femoroacetabular impingement syndrome (FAIS) is a common condition of the hip that can cause significant damage to the joint, leading to degeneration and osteoarthritis. FAIS constitutes an abnormal and dynamic contact between the femoral head-neck junction and the acetabular rim, resulting from altered bone morphology at one or both sites. Repetitive trauma at the site of impingement generates progressive damage to the acetabular labrum, chondrolabral junction, and articular cartilage.

View Article and Find Full Text PDF

Ankle push-off is important for efficient, human-like walking, and many prosthetic devices mimic push-off using motors or elastic elements. The knee is extended throughout the stance phase and begins to buckle just before push-off, with timing being crucial. However, the exact mechanisms behind this buckling are still unclear.

View Article and Find Full Text PDF

This study evaluates the API 650 design procedure for steel storage tanks, incorporating nonlinear dynamic analysis with large deformation effects. Focusing on seismic vulnerability, the case study examines storage tanks proposed for construction in Naples, Italy, assessing their performance under site-specific seismic conditions. A target spectrum and 20 earthquake records were selected to reflect regional seismic characteristics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!