Aims: We sought to determine which echocardiographic markers of left ventricular (LV) remodeling and diastolic dysfunction can contribute as incremental and independent prognostic information in addition to current clinical risk markers of ischemic LV systolic dysfunction in the Surgical Treatment for Ischemic Heart Failure (STICH) trial.

Methods And Results: The cohort consisted of 1511 of 2136 patients in STICH for whom baseline transmitral Doppler (E/A ratio) could be measured by an echocardiographic core laboratory blinded to treatment and outcomes, and prognostic value of echocardiographic variables was determined by a Cox regression model. E/A ratio was the most significant predictor of mortality amongst diastolic variables with lowest mortality for E/A closest 0.8, although mortality was consistently low for E/A 0.6 to 1.0. Mortality increased for E/A < 0.6 and > 1.0 up to approximately 2.3, beyond which there was no further increase in risk. Larger LV end-systolic volume index (LVESVI) and E/A < 0.6 and > 1.0 had incremental negative effects on mortality when added to a clinical multivariable model, where creatinine, LVESVI, age, and E/A ratio accounted for 74% of the prognostic information for predicting risk. LVESVI and E/A ratio were stronger predictors of prognosis than New York Heart Association functional class, anemia, diabetes, history of atrial fibrillation, and stroke.

Conclusions: Echocardiographic markers of advanced LV remodeling and diastolic dysfunction added incremental prognostic value to current clinical risk markers. LVESVI and E/A ratio outperformed other markers and should be considered as standard in assessing risks in ischemic heart failure. E/A closest to 0.8 was the most optimal filling pattern.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7257201PMC
http://dx.doi.org/10.1186/s12947-020-00195-1DOI Listing

Publication Analysis

Top Keywords

e/a ratio
20
remodeling diastolic
12
incremental prognostic
8
left ventricular
8
ventricular remodeling
8
echocardiographic markers
8
diastolic dysfunction
8
current clinical
8
clinical risk
8
risk markers
8

Similar Publications

Background Doxorubicin is an important drug used in the treatment of children with acute leukemia, and cardiotoxicity is the most serious complication due to its use. The cardiac dysfunction due to doxorubicin can be acute, early, or late. Echocardiography is a non-invasive tool and can be employed to detect clinical and subclinical cardiac dysfunction and plan treatment strategies accordingly.

View Article and Find Full Text PDF

Purpose: The effect of metabolic factors on cardiovascular risk in obstructive sleep apnea (OSA) is unclear. This study aimed to investigate the effect of metabolic factors on the left ventricular diastolic function in patients with OSA.

Patients And Methods: This cross-sectional study included a total of 478 patients with OSA from September 2018 to September 2023.

View Article and Find Full Text PDF

Background: Sepsis-associated encephalopathy (SAE) may be worsened by early systemic insults. We aimed to investigate the association of early systemic insults with outcomes of critically ill patients with severe SAE.

Methods: We performed a retrospective analysis using data from the French OUTCOMEREA prospective multicenter database.

View Article and Find Full Text PDF

Photon-Counting CT Effects on Sensitivity for Liver Lesion Detection: A Reader Study Using Virtual Imaging.

Radiology

January 2025

From the Department of Radiology, Duke University Hospital, 2301 Erwin Rd, Box 3808, Durham, NC 27701 (B.W.T., K.R.K., B.C.A., S.P.T., D.E.K., B.H., M.R.B., D.M., E.S., E.A.); Department of Biostatistics and Bioinformatics (N.F., S.M., A.E.) and Department of Medical Physics (W.P.S., E.S., E.A.), Duke University, Durham, NC.

Background Detection of hepatic metastases at CT is a daily task in radiology departments that influences medical and surgical treatment strategies for oncology patients. Purpose To compare simulated photon-counting CT (PCCT) with energy-integrating detector (EID) CT for the detection of small liver lesions. Materials and Methods In this reader study (July to December 2023), a virtual imaging framework was used with 50 anthropomorphic phantoms and 183 generated liver lesions (one to six lesions per phantom, 0.

View Article and Find Full Text PDF

NiMnZ (Z = In, Sn or Sb) undergo martensitic transformation with transformation temperature () scaling with the average valence electron per atom (/) ratio. However, the rate of increase of depends on the type of Z atom, with the slope of / curve increasing from Z = In to Z = Sb. Local structural distortions are believed to be the leading cause of martensitic transformation in these alloys.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!