A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of façade orientation on the leaching of biocides from building façades covered with mortars and plasters. | LitMetric

Biocides used in building façades to prevent potential growth of algae, fungi and bacteria are of major concern regarding the quality of stormwater runoff. The aim of the study was to analyze the influence of the façade orientation on the biocide release under real weather conditions to gain information for the development of on-site treatment systems. Field tests with model houses containing two different plaster compositions were carried out over a period of 18 months. The results of the analyzed rain events demonstrate that façade orientation plays an important role in the leaching loads of biocides. Biocide loads in the runoff decreased corresponding to the wind direction. High cumulated active substance discharges of diuron (149 mg/m), carbendazim (43.5 mg/m), terbutryn (9.3 mg/m) and octylisothiazolinone (OIT) (31.9 mg/m) were found in the runoff of the façades facing the predominant weather orientation. Meanwhile, the highest concentrations of diuron (2.8 mg/L) and OIT (0.7 mg/L) were observed in the runoff from façades with smaller runoff volumes. The obtained results demonstrate that treatment facilities have to be installed at all building sides. The hydraulic and the substance load is highest at the weather side, which has a strong influence on the dimension and the lifetime of the treatment system.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2020.139465DOI Listing

Publication Analysis

Top Keywords

façade orientation
12
influence façade
8
biocides building
8
building façades
8
runoff façades
8
runoff
5
orientation
4
orientation leaching
4
leaching biocides
4
façades
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!