Background: Contraction of the esophagus was observed during cryoablation for paroxysmal atrial fibrillation (PAF). The purpose of this study is to investigate the mechanism of esophageal contraction and the correlation between the contraction and esophageal thermal lesions.

Methods: This prospective study enrolled 64 patients with PAF undergoing second-generation cryoballoon (CB2) ablation for pulmonary vein isolation (PVI). During PVI for the left inferior pulmonary vein, contrast esophagography was performed before and during cryoablation. The sample population was divided into two groups: A (31 patients) and B (33 patients). Group A consisted of patients in whom the distal half of the CB was in proximity to the esophagus, while for group B the esophagus was away from the distal half of the CB. Esophageal contraction was recorded as a variation in the width of the esophageal lumen during PVI. Postablation esophageal endoscopy was done on all patients.

Results: The reduction in the width of the esophageal lumen in group A was greater than in group B during freezing (40.12 ± 23.24% vs 8.14 ± 10.35%, P < .001). Following endoscopy, no apparent esophageal lesion was detected in all patients.

Conclusion: The extent of esophageal contraction is correlated with the positioning of the esophagus at the distal half of the CB. The findings of this study indicate that esophageal contraction during freezing may be a self-protective mechanism.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pace.13967DOI Listing

Publication Analysis

Top Keywords

esophageal contraction
12
pulmonary vein
8
distal half
8
width esophageal
8
esophageal lumen
8
esophageal
7
contraction cryoablation
4
cryoablation protective
4
protective mechanism
4
mechanism background
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!