Background: Clinical and hemodynamic consequences of flow diverters extending from the M1 to the internal carotid artery (ICA), covering the A1 segment, have rarely been investigated. We aimed to provide angiographic and clinical data about flow modifications on the covered A1.

Methods: Consecutive patients receiving M1-ICA flow diverters for unruptured aneurysms were collected from our prospective database (2014-2020).

Results: 42 A1 arteries covered with a single device were studied. All patients had an angiographic detected contralateral flow from the anterior communicating artery (AcomA). Immediately after flow diversion, 20 (47.6%) covered A1 showed slow flow. During a mean angiographic follow-up of 14 months, 13 (31%) and 22 (52.3%) A1 arteries were occluded and narrowed, respectively. Flow changes were asymptomatic in all cases. Vascular risk factors, sex, oversized compared with not oversized stents, immediate A1 slow flow, age, diameter of the A1, length of follow-up, and platelet inhibition rate were tested as prognosticators of A1 occlusion. Length of the angiographic follow-up was the only predictor of A1 occlusion (p=0.005, OR=3, CI=1.4 to 6.7). There were two device related ischemic events with a 2.3% rate of morbidity (one basal ganglia infarct after coverage of the M1 perforators and one transient acute instent thrombosis).

Conclusions: Covering the A1 segment during M1-ICA flow diversion seems relatively safe, if the contralateral flow is assured by the AcomA. Approximately 31% and 52% of the covered A1 showed asymptomatic occlusions and narrowing, respectively. The likelihood of flow modification was proportional to the length of follow-up. Morbidity associated with flow diversion in the ICA terminus region was 2.3%.

Download full-text PDF

Source
http://dx.doi.org/10.1136/neurintsurg-2020-016051DOI Listing

Publication Analysis

Top Keywords

flow
14
carotid artery
12
flow diversion
12
flow modification
8
internal carotid
8
flow diverters
8
covering segment
8
m1-ica flow
8
contralateral flow
8
slow flow
8

Similar Publications

Objectives: PD15, a novel natural steroidal saponin extracted from the rhizomes of Paris delavayi Franchet, has demonstrated a strong cytotoxic effect against HepG2 and U87MG cells. However, its therapeutic effects on colorectal cancer (CRC) and the underlying molecular mechanisms remain unclear.

Methods: MTT assay, clonogenic assay, Hoechst 33258 staining, flow cytometry, molecular docking, and western blot were used to investigate the mechanism of PD15 in HCT116 cell lines.

View Article and Find Full Text PDF

Objective: The study aims to develop continuous trajectory profiles along curves with minimal error. It also focuses on formulating a percentage trajectory transection rate model as a function of geometric parameters (e.g.

View Article and Find Full Text PDF

Objective: Although the efficacy of high-flow nasal oxygen therapy in delaying or avoiding intubation in patients with hypoxemic respiratory failure has been studied, its potential for facilitating early weaning from invasive mechanical ventilation remains unexplored.

Methods: In this randomized controlled trial, 80 adults with acute hypoxemic respiratory failure requiring invasive mechanical ventilation for > 48 hours were enrolled and divided into two groups: conventional weaning and early weaning via high-flow nasal oxygen. In the conventional weaning group, the spontaneous breathing trial was performed after the PaO2/FiO2 ratio was ≥ 200, whereas in the high-flow nasal oxygen group, the spontaneous breathing trial was conducted earlier when the PaO2/FiO2 ratio was 150 - 200.

View Article and Find Full Text PDF

Color doppler blood flow analysis in circumscribed choroidal hemangioma.

Arq Bras Oftalmol

January 2025

Department of Ophthalmology & Visual Sciences, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.

Purpose: To evaluate if color Doppler can detect internal blood flow in circumscribed choroidal hemangioma.

Methods: This cross-sectional study examined seven eyes of seven participants with circumscribed choroidal hemangiomas, with or without prior treatment. B-scan ultrasound and color Doppler were used to assess the dimensions, topographical distribution, and internal blood flow of the affected eyes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!