AI Article Synopsis

  • The study aimed to identify factors influencing hidden blood loss (HBL) during percutaneous vertebroplasty (PVP) treatments for patients with osteoporotic vertebral compression fractures (OVCFs).
  • Researchers analyzed clinical data from 125 patients, examining various diagnostic imaging results and performing blood tests before and after surgery to assess hidden blood loss and its potential risk factors.
  • Findings showed that factors like diabetes, the number of surgical segments, vertebral height loss and recovery rates, and cement leakage significantly increased hidden blood loss, while bone mineral density and hypertension had no notable impact.

Article Abstract

Objective: To investigate the influencing factors of hidden blood loss (HBL) during the treatment of percutaneous vertebroplasty (PVP).

Methods: The clinical data of 125 patients with osteoporotic vertebral compression fractures (OVCFs) treated with percutaneous vertebroplasty from March 2016 to December 2017 were retrospectively analyzed. All patients underwent X rays of the AP and lateral lumbar spine, double oblique, and dynamic positions. Lumbar spine CT, MRI, and dual energy X ray bone densitometer (DXA) were used to confirm the diagnosis. There were 55 males and 70 females, 10 cases of thoracic vertebrae, 89 cases of thoracolumbar vertebrae, 26 cases of lumbar vertebrae, 87 cases with single segment, 29 cases with double segment,and 9 cases with 3 segments. The vertebral compression height ratios of 67 patients were less than 1 / 3, and the ratios for 41 patients were from 1 / 3 to 2 / 3,for 17 patients were more than 2 / 3. Blood routine examination were performed before and 3 days after surgery to analyze hidden blood loss and to explore its risk factors.

Results: The average hidden blood loss was (317±156) ml in 125 patients. Multiple linear regression analysis revealed a history of diabetes(=0.011),surgical segments(=0.036),number of segments (<0.001),vertebral height loss rate (=0.002),vertebral height recovery rate (<0.001) and bone cement leakage rate (=0.003) were positively correlated with hidden blood loss. Moreover,it was found that the blood loss was higher in those with higher vertebral height loss rate than in those with lower vertebral height loss rate, and the blood loss was higher in those with good vertebral height recovery than those with poor vertebral height recovery. Additionally,the cement leakage was also an important factor in increasing hidden blood loss. However,there was no significant correlation between bone mineral density(=0.814) or history of hypertension(=0.055) and hidden blood loss.

Conclusion: Patients with OVCFs have a large amount of hidden blood loss after PVP treatment, which needs attention. At the same time, the history of diabetes, surgical segments, number of segments, bone cement leakage rate, vertebral height loss rate and vertebral height recovery rate are the risk factors for hidden blood loss.

Download full-text PDF

Source
http://dx.doi.org/10.12200/j.issn.1003-0034.2020.05.011DOI Listing

Publication Analysis

Top Keywords

hidden blood
16
blood loss
16
vertebral compression
12
vertebrae cases
12
osteoporotic vertebral
8
compression fractures
8
percutaneous vertebroplasty
8
125 patients
8
lumbar spine
8
ratios patients
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!