. This pilot study evaluates if an electronic nose (eNose) can distinguish patients at risk for recurrent hernia formation and aortic aneurysm patients from healthy controls based on volatile organic compound analysis in exhaled air. Both hernia recurrence and aortic aneurysm are linked to impaired collagen metabolism. If patients at risk for hernia recurrence and aortic aneurysms can be identified in a reliable, low-cost, noninvasive manner, it would greatly enhance preventive options such as prophylactic mesh placement after abdominal surgery. . From February to July 2017, a 3-armed proof-of-concept study was conducted at 3 hospitals including 3 groups of patients (recurrent ventral hernia, aortic aneurysm, and healthy controls). Patients were measured once at the outpatient clinic using an eNose with 3 metal-oxide sensors. A total of 64 patients (hernia, n = 29; aneurysm, n = 35) and 37 controls were included. Data were analyzed by an automated neural network, a type of self-learning software to distinguish patients from controls. . Receiver operating curves showed that the automated neural network was able to differentiate between recurrent hernia patients and controls (area under the curve 0.74, sensitivity 0.79, and specificity 0.65) as well as between aortic aneurysm patients and healthy controls (area under the curve 0.84, sensitivity 0.83, and specificity of 0.81). . This pilot study shows that the eNose can distinguish patients at risk for recurrent hernia and aortic aneurysm formation from healthy controls.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7804369PMC
http://dx.doi.org/10.1177/1553350620917898DOI Listing

Publication Analysis

Top Keywords

aortic aneurysm
20
healthy controls
16
hernia recurrence
12
recurrence aortic
12
distinguish patients
12
patients risk
12
recurrent hernia
12
patients
10
hernia
8
proof-of-concept study
8

Similar Publications

Background And Objective: Patients with thoracic aortic aneurysm and dissection (TAAD) are often asymptomatic but present acutely with life threatening complications that necessitate emergency intervention. Aortic diameter measurement using computed tomography (CT) is considered the gold standard for diagnosis, surgical planning, and monitoring. However, manual measurement can create challenges in clinical workflows due to its time-consuming, labour-intensive nature and susceptibility to human error.

View Article and Find Full Text PDF

Introduction: Compared to aortic dissection and isolated visceral artery dissection, multiple peripheral arterial dissections have not been formally reported to date. Currently, there is no well-established treatment for this condition, and large-scale studies with extensive sample data are lacking.

Case Presentation: A 56-year-old male, was provisionally diagnosed with " idiopathic multiple peripheral arterial dissections.

View Article and Find Full Text PDF

Background: Abdominal aortic aneurysm (AAA) is characterized by the proteolytic breakdown of the extracellular matrix, leading to dilatation of the aorta and increased risk of rupture. Biomarkers that can predict major adverse aortic events (MAAEs) are needed to risk stratify patients for more rigorous medical treatment and potential earlier surgical intervention.

Objectives: The primary objective was to identify the association between baseline levels of these biomarkers and MAAEs over a period of 5 years.

View Article and Find Full Text PDF

Management of Aorto-Duodenal Fistula: Case Series and Technical Notes.

Ann Ital Chir

January 2025

Chirurgia Vascolare, PO Belcolle, ASL Viterbo, 01100 Viterbo, Italy.

Aorto-duodenal fistula (ADF) is a rare clinical condition characterized by abnormal communication between the 3rd or 4th portion of the duodenum and the aorta, typically associated with aneurysmal disease. The incidence of ADF is expected to increase, however, there remains a lack of consensus on the optimal approach for intestinal restoration. In this study, we present three cases of ADF and their respective treatments using three distinct surgical techniques.

View Article and Find Full Text PDF

Background: Patients with pulmonary atresia and ventricular septal defect (PA/VSD) are prone to progressive aortic dilation. However, there are relatively few reports of progressive development of aortic aneurysm or aortic dissection in adult patients who missed early corrective surgery.

Presentation Of Cases: Case 1: A 38-year-old man with PA/VSD and a bicuspid aortic valve (BAV), underwent VSD repair, aortic valve replacement, and PA correction at age 21.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!