Purpose: Robotically-assisted total knee arthroplasty (TKA) has been shown to improve alignment and decrease outliers, an important goal in TKA procedures. The purpose of this cadaveric study was to compare the accuracy and reproducibility of a recently introduced TKA robotic system to conventional instrumentation for bone resections.

Methods: This cadaveric study compared 14 robotically-assisted TKA with 20 conventional TKAs. Four board-certified high volume arthroplasty surgeons with no prior experience in robotics (except one) performed the procedures with three different implant systems. Angle and level of bone resections obtained from optical navigation or calliper measurements were compared to the intra-operative plan to determine accuracy. Group comparison was performed using Student t test (mean) and F test (variance), with significance at p < 0.05.

Results: The robotic group demonstrated statistically more accurate results (p < 0.05) and fewer outliers (p < 0.05) than conventional instrumentation when aiming for neutral alignment. Final limb alignment (HKA) had an accuracy of 0.8° ± 0.6° vs 2.0° ± 1.6°, with 100% vs 75% of cases within 3° and 93% vs 60% within 2°. For the robotically-assisted knees, the accuracy of bone resection angles was below 0.6° with standard deviations below 0.4°, except for the femur flexion (1.3° ± 1.0°), and below 0.7 mm with standard deviations below 0.7 mm for bone resection levels.

Conclusion: This in vitro study has demonstrated that this novel TKA robotic system produces more accurate and more reproducible bone resections than conventional instrumentation. It supports the clinical use of this new robotic system.

Level Of Evidence: Cadaveric study, Level V.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-020-06038-wDOI Listing

Publication Analysis

Top Keywords

cadaveric study
12
accuracy reproducibility
8
total knee
8
knee arthroplasty
8
conventional instrumentation
8
better accuracy
4
reproducibility robotically-assisted
4
robotically-assisted system
4
system total
4
arthroplasty compared
4

Similar Publications

Purpose: The objective was to use cyclic tensile loading to compare the gap formation at suture site of three different suture materials to repair bovine radial meniscal tears: (1) polyglactin sutures, (2) tough adhesive puncture sealing (TAPS) sutures and (3) ultra-high molecular weight polyethylene (UHMWPE) sutures.

Methods: Twelve ex vivo bovine knees were dissected to retrieve the menisci. Complete radial tears were performed on 24 menisci, which were then separated into three groups and repaired using either pristine 2-0 polyglactin sutures, TAPS sutures (2-0 polyglactin sutures coated with adhesive chitosan/alginate hydrogels) or 2-0 UHMWPE sutures with a single stitch.

View Article and Find Full Text PDF

Background: This study aims to evaluate the impact of different thresholds and voxel sizes on the accuracy of Cone-beam computed tomography (CBCT) tooth reconstruction and to assess the accuracy of fused CBCT and intraoral scanning (IOS) tooth models using curvature continuity algorithms under varying thresholds and voxel conditions.

Methods: Thirty-two isolated teeth were digitized using IOS and CBCT at two voxel sizes and five threshold settings. Crown-root fusion was performed using a curvature continuity algorithm.

View Article and Find Full Text PDF

The unique saddle articulation of the trapeziometacarpal joint allows for a wide range of motion necessary for routine function of the thumb. Inherently unstable characteristics of the joint can lead painful instability. In this study, we modified a surgical dorsal ligament reconstruction technique for restoring trapeziometacarpal joint stability.

View Article and Find Full Text PDF

Rare bilateral vascular variations of the upper limb: a cadaveric case study.

J Cardiothorac Surg

December 2024

Centre for Human Anatomy Education, Department of Anatomy and Developmental Biology, Biomedical Discovery Institute, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Australia.

Arterial variations in the upper limb are of significant clinical importance, especially in procedures such as venepunctures, coronary artery bypass grafts, trauma reconstructive surgeries, brachial plexus nerve blocks, and breast reconstructions. This report presents previously undocumented arterial variations in the upper limbs in a 95-year-old female cadaveric donor. We observed bilateral superficial ulnar arteries originating at the cubital fossa, deviating from the previously reported origin at the proximal brachial artery.

View Article and Find Full Text PDF

Range of Flexion Improvement in Degenerative Stages of the First Metatarsophalangeal Joint () with Cross-Linked Hyaluronic Acid: A Cadaveric Study.

J Funct Morphol Kinesiol

December 2024

Human Anatomy and Embryology Unit, Experimental Pathology and Therapeutics Department, Faculty of Medicine and Health Sciences, University of Barcelona, 08907 Hospitalet, Spain.

Background: Viscosupplementation consists of intraarticular hyaluronic acid injections applied to treat pain and improve joint mobility. The objective of the study was to analyze the improvement of the range of mobility of the first metatarsophalangeal joint with a single dose of cross-linked hyaluronic acid.

Methods: Ten fresh frozen specimens of feet sectioned below the knee were selected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!