Ultrathin glass fiber microprobe for electroporation of arbitrary selected cell groups.

Bioelectrochemistry

Department of Glass, Institute of Electronic Materials Technology, Wolczyńska 133, 01-919, Warsaw, Poland; Faculty of Physics, Warsaw University, Pasteura 7, 02-093 Warsaw Poland. Electronic address:

Published: October 2020

A new type of ultrathin fiber microprobe for selective electroporation is reported. The microprobe is 10 cm long and has a diameter of 350 µm. This microprobe is a low cost tool, which allows electroporation of an arbitrary selected single cell or groups of cells among population with use of a standard microscope and cell culture plates. The microprobe in its basic form contains two metal microelectrodes made of a silver-copper alloy, running along the fiber, each with a diameter of 23 µm. The probe was tested in vitro on a population of normal and cancer cells. Successful targeted electroporation was observed by means of accumulation of trypan blue (TB) dye marker in the cell. The electroporation phenomenon was also verified with propidium iodide and AnnexinV in fluorescent microscopy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bioelechem.2020.107545DOI Listing

Publication Analysis

Top Keywords

fiber microprobe
8
electroporation arbitrary
8
arbitrary selected
8
cell groups
8
microprobe
5
electroporation
5
ultrathin glass
4
glass fiber
4
microprobe electroporation
4
cell
4

Similar Publications

pH is an important physiological parameter within organisms, playing a crucial role in functional activities in cells and tissues. Among various pH sensing methods, optical fiber pH sensors have gained a wide attention due to their unique advantages. However, current silica optical fiber-based pH sensors face some challenges such as weak biocompatibility, low biological safety, complex or unstable surface modification.

View Article and Find Full Text PDF

Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell.

Anal Chem

January 2025

School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.

A linear spot-type multipass cell-enhanced fiber-optic photoacoustic gas microprobe is proposed. To further reduce the volume of the gas chamber and enhance the photoacoustic signal, we designed the cross section of the photoacoustic tube as a slit with a height of 10 mm and a width of 1.5 mm.

View Article and Find Full Text PDF

Asbestos exposure diagnosis in pulmonary tissues.

Pathologica

August 2024

Research Training Innovation Infrastructure, Research and Innovation Department (DAIRI), Azienda Ospedaliero-Universitaria SS. Antonio e Biagio e Cesare Arrigo, Alessandria, Italy.

Article Synopsis
  • The diagnosis of asbestosis varies between clinical settings and medical/legal contexts, where the presence of asbestos bodies (ABs) is crucial for a legal classification of the disease.
  • Identifying ABs can be challenging with light microscopy; however, other factors like work history and imaging are also important in making a diagnosis.
  • Newer methods like micro-Raman spectroscopy and SEM/EDS allow for better analysis of asbestos fibres in tissue without extensive manipulation, highlighting the need for collaboration among professionals in the diagnostic process.
View Article and Find Full Text PDF

Optical fiber Raman and surface-enhanced Raman scattering (SERS) probes hold great promise for in vivo biosensing and in situ monitoring of hostile environments. However, the silica Raman scattering background generated within the optical fiber increases in proportion to the length of the fiber, and it can swamp the signal from the target analyte. While filtering can be applied at the distal end of the fiber, the use of bulk optical elements has limited probe miniaturization to a diameter of 600 µm, which in turn limits the potential applications.

View Article and Find Full Text PDF

In this paper, a fiber optic microprobe displacement sensor is proposed considering characteristics of micro-Michelson interference structure and its components. The principal error of micro Fabry-Perot interferometric structure is avoided, and high-precision interferometric displacement measurement is realized. The collimated microprobe and convergent microprobe are analyzed, simulated, and designed for the purposes of measuring long-distance displacement and small spot rough surface, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!