Background And Objective: Ultrasound diaphragmatic muscle motion characteristics may provide useful information about normal or abnormal diaphragmatic function and indicate diaphragmatic weakness, or paralysis. In the present work we propose and evaluate an integrated semi-automated analysis system for the quantitative analysis of ultrasonic motion from ultrasound diaphragmatic videos.

Methods: The proposed system was evaluated in simulated videos and in 13 patients, four of whom patients were mechanically ventilated. The major steps of the methodology were as follows: video normalization, despeckle filtering, generation of an M-Mode image, snakes segmentation, and motion measurements.

Results: The following manual (-/) vs semi-automated (/-), (median±IQR) measurements, which are routinely carried out by the experts, for assessing the severity of the disease, were computed. For the simulated videos the diaphragmatic excursion was 1.80±0.00 cm / 1.76±0.03 cm. For all the real ultrasound videos investigated in this study the following measurements were computed: (i) diaphragmatic excursion: 0.84±0.15 cm / 0.83±0.14 cm, (ii) inspiration time (T): 0.71±0.18 sec / 0.70±0.15 sec, (iii) total breathing time for one cycle (T): 1.71±0.37 sec / 1.67±0.37 sec, (iv) diaphragmatic curve slope: 1.29±0.36 cm/sec / 1.27±0.36 cm/sec, and (v) relaxation rate (RR): 0.82±0.17 cm/sec / 0.82±0.18 cm/sec.

Conclusions: Manual and semi-automated measurements were very close with non-statistical significant differences and strong correlations between them. It is anticipated that the proposed system might be useful in the clinical practice in the assessment and follow up of patients with diaphragmatic weakness or paralysis and aid in the separation of normal and abnormal diaphragmatic motion. Further validation and additional experimentation in a larger sample of videos and different patient groups is required.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2020.105517DOI Listing

Publication Analysis

Top Keywords

ultrasound diaphragmatic
12
manual semi-automated
12
diaphragmatic
9
normal abnormal
8
abnormal diaphragmatic
8
diaphragmatic weakness
8
weakness paralysis
8
proposed system
8
simulated videos
8
diaphragmatic excursion
8

Similar Publications

Cranioventral pulmonary consolidation (CVPC) is a common lesion observed in the lungs of slaughtered pigs, often associated with Mycoplasma (M.) hyopneumoniae infection. There is a need to implement simple, fast, and valid CVPC scoring methods.

View Article and Find Full Text PDF

Chilaiditi Sign and Syndrome as a Finding in the Emergency Room: A Case Report.

Cureus

December 2024

Clinical Pathology Department, Unidade Local de Saúde do Nordeste, Unidade Hospitalar de Bragança, Bragança, PRT.

The Chilaiditi sign is the presence of a loop of bowel interposed between the liver and the diaphragm. In most cases, the Chilaiditi sign is diagnosed as a rare incidental radiological finding on chest X-rays or the abdomen of asymptomatic patients. When associated with symptoms, it is named Chilaiditi syndrome.

View Article and Find Full Text PDF

Background: Obesity is an alarmingly increasing global public health issue. Laparoscopic sleeve gastrectomy (LSG) is the most common bariatric surgery owing to its simplicity, effectiveness, and low complication rates. The complications can be classified as early or late, with fistula formation being one of the most severe complications.

View Article and Find Full Text PDF

Implantable Passive Sensors for Biomedical Applications.

Sensors (Basel)

December 2024

School of Electrical and Computer Engineering, National Technical University of Athens, 15772 Athens, Greece.

Article Synopsis
  • Implantable sensors are becoming popular for localized and continuous monitoring in medical settings, allowing for early detection and timely interventions.
  • There are two main types of implantable sensors: active, which have more advanced functionalities but require a power source, and passive, which don't need power and offer simpler, smaller designs.
  • This review focuses on passive sensor technologies, discussing their materials, detection methods, clinical applications, advantages over active sensors, and important considerations for their packaging and compatibility with the human body.
View Article and Find Full Text PDF

Relationship Between Diaphragm Function and Sarcopenia Assessed by Ultrasound: A Cross-Sectional Study.

Diagnostics (Basel)

January 2025

Department of General Medicine, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 113-8510, Japan.

: The diaphragm is important for respiration, but the effects of age-related muscle loss and sarcopenia on diaphragm function are unclear. We evaluated the associations of sarcopenia and skeletal muscle mass (SMM) with diaphragm function. : This study was conducted at three Japanese hospitals from May 2023 to September 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!