A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Calibration of a physical functioning item bank for measurement of health-related quality of life in Singapore. | LitMetric

Purpose: We aimed to develop and calibrate an item bank to measure physical function (PF) in Singapore, a multi-ethnic city in Southeast Asia.

Methods: We recruited participants from community and hospital settings stratified for age and gender, with and without medical conditions to administer candidate pool of 61-items derived from the people's perspectives. We calibrated their responses using Samejima's graded response model of item response theory (IRT), including model assumptions, model fit, differential item functioning (DIF), and concurrent and known-groups validity.

Results: 496 participants (50% male; 41% above 50 years old; 33.3% Chinese, 32.7% Malay and 34.1% Indian; 35% without chronic illness) were included in the calibration of item bank. 6 items were excluded due to mis-fit and local dependence. Redundancies in the response level was collapsed and re-scoring, while preserving the 5-level response structure. We found the final 55-item PF bank had adequate fit to IRT assumptions of unidimensionality, local independence and monotonicity. Items generally showed discernible ceiling effects with latent scores between - 3.5 to + 1.5. We found no DIF with gender, ethnicity or education. The PF scores correlated in the hypothesized direction with self-reported global health (Spearman's rho =  - 0.35, 95% confidence intervals - 0.43 to - 0.27) and discriminated between groups stratified by age, gender and medical conditions.

Conclusion: The 55-item Singapore PF item bank provides an adequate tool for measuring the lower end of PF, with greatest potential utility in healthcare settings where restoration to normal physical functioning is the goal of intervention.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11136-020-02535-0DOI Listing

Publication Analysis

Top Keywords

item bank
16
physical functioning
8
stratified age
8
age gender
8
gender medical
8
bank adequate
8
item
6
bank
5
calibration physical
4
functioning item
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!