New Comprehensive Reference Values for Arterial Vascular Parameters in Children.

J Am Soc Echocardiogr

Labatt Family Heart Centre, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada; SickKids Research Institute, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada.

Published: August 2020

Background: Noninvasive measurements of vascular parameters can be used for the detection and risk stratification of cardiovascular diseases. Most vascular parameters are influenced by age and body size, but pediatric reference values are scarce and limited to a few parameters. The aim of this study was to develop pediatric reference values and Z score equations for a comprehensive set of vascular parameters.

Methods: A total of 292 healthy subjects aged 0 to 18 years were prospectively recruited. Stiffness index β, pressure-strain elastic modulus, common carotid intima-media thickness, brachial flow-mediated dilation, radial augmentation index, central and right arm peripheral artery pulse-wave velocities, and pulse-wave velocity ratio were assessed. Normalization for age and anthropometric variables was performed using parametric multivariate regression modeling. Z scores were assessed for heteroscedasticity, residual association with age and body size, and distribution.

Results: Multivariate regression models with various combinations of height, weight, and age were used to obtain Z scores that were independent of age and body size. There was no residual association between Z scores and body size, age, or body mass index. There was no significant departure from the normal distribution.

Conclusions: The authors present reference values and Z score equations for a comprehensive set of vascular parameters during childhood. Further studies are necessary to assess their usefulness in detecting the vascular signs of subclinical atherosclerosis and chronic diseases, including congenital heart disease.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2020.03.001DOI Listing

Publication Analysis

Top Keywords

reference values
16
vascular parameters
16
age body
16
body size
16
pediatric reference
8
values score
8
score equations
8
equations comprehensive
8
comprehensive set
8
set vascular
8

Similar Publications

Introduction: In asymptomatic subjects, variations of sagittal alignment parameters according to age and pelvic incidence (PI) has been reported. The aim of this observational study was to describe thoraco-lumbar sagittal alignment in patients with degenerative scoliosis and to compare them to asymptomatic individuals, seeking for the specific effect of deformity in similar age and PI groups.

Materials And Methods: Full spine radiographs of 235 asymptomatic subjects and 243 scoliosis patients were analyzed: cervico-thoracic inflexion point (CTIP), thoraco-lumbar inflexion point (TLIP), lumbar lordosis (LL) L1-S1, LL (TLIP-S1), LL superior arch (TLIP-lumbar apex), LL inferior arch (lumbar apex-S1), PI, thoracic kyphosis (TK) T5-T12, TK T1-T12, number of vertebrae CTIP-TLIPandTLIP-S1.

View Article and Find Full Text PDF

Low-grade infections in nonunion of the femur and tibia without clinical suspicion of infection - Incidence, microbiology, treatment, and outcome.

Injury

January 2025

Institute for Biomechanics, Paracelsus Medical University, Strubergasse 21, 5020 Salzburg, Austria; Department of Trauma Surgery, BG Unfallklinik Murnau, Professor-Küntscher-Str. 8, 82418 Murnau am Staffelsee, Germany.

Treatment algorithms for fracture nonunion depend on the presence or absence of bacterial infection. However, it is often impossible to identify infection preoperatively. While some infections may present with clinical signs of infection, low-grade infections lack infection signs and have a clinical presentation similar to aseptic nonunion.

View Article and Find Full Text PDF

Daratumumab followed by tocilizumab for treatment of late antibody-mediated rejection in renal transplant recipients with high or moderate levels of de novo donor-specific antibodies: a pilot study.

BMC Nephrol

January 2025

Institute of Organ Transplantation, Tongji Hospital, Tongji Medical College, Key Laboratory of Organ Transplantation, NHC Key Laboratory of Organ Transplantation, Key Laboratory of Organ Transplantation, Huazhong University of Science and Technology, Ministry of Education, Chinese Academy of Medical Sciences, Wuhan, China.

Background: Effective treatment of late antibody-mediated rejection (late AMR) is still an unmet medical need. Clearing donor-specific antibody (DSA) and preventing its rebound is the ideal goal of treatment.

Methods: We have summarized the clinical data from seven patients with late or chronic active AMR after renal transplantation who received daratumumab (Dara)-based treatment first (Phase 1) and then tocilizumab (TCZ) therapy (Phase 2).

View Article and Find Full Text PDF

Agreement between methods to assess potassium intake in patients with chronic kidney disease.

Clin Nutr ESPEN

January 2025

Post Graduation Program in Medical Science, Rio de Janeiro State University, Rio de Janeiro, 20550-900, Brazil; Department of Applied Nutrition, Nutrition Institute, Rio de Janeiro State University, Rio de Janeiro, 20550-900, Brazil. Electronic address:

Background & Aims: In the general population, 24-hour urine potassium excretion is considered the reference standard for estimating potassium intake. However, its agreement with food records and spot urine collections in adults living with chronic kidney disease (CKD) is not well-established. Given the risk of hyperkalemia related to changes in renal potassium handling, understanding if this reference standard is appropriate for the CKD population is important.

View Article and Find Full Text PDF

Adding colour to ion-selective membranes.

Talanta

January 2025

Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093, Warsaw, Poland. Electronic address:

An idea of using ion-exchanger salt containing optically active cations to prepare ion-selective membranes is proposed. Although the presence of an ion-exchanger in the composition of neutral ionophore based sensors is necessary, the choice of available salts for cation-selective sensors preparation, is usually limited to sodium or potassium compounds. In this work we propose application of an alternative salt, using a cation optically active both in absorption and emission mode as a mobile one.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!