Comparison of Intraoral and Extraoral Digital Scanners: Evaluation of Surface Topography and Precision.

Dent J (Basel)

Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, MA 02115, USA.

Published: May 2020

The aim of this study was to evaluate the surface topography and the precision measurements of different intraoral and extraoral digital scanners. A reference model of a maxillary arch with four implant analogs was prepared and scanned by three intraoral and two extraoral scanners. The reference model was scanned fifteen times with each digital scanning system, investigating the surface topography and precision measurements for the same-arch and cross-arch measurements. The data was exported to 3D inspection and mesh-processing software (GOM Inspect, Braunschweig, Germany). Statistical analysis was performed using a one-way Analysis of Variance (ANOVA) with the Tukey method for pairwise comparisons. The effect of parameters on generating the surface topography was analyzed by Univariate Linear Regression Analysis. Of the scanner systems evaluated, iTero (IT) exhibited the most number of triangulation points, followed by Trios 3 Shape (TR) and Straumann Cares (SC). There were no significant differences observed in the surface topography when comparing flat and contoured surfaces, the anterior and posterior position, and interproximal areas. For the precision measurement in the same quadrant, no statistical difference was noted between intra- and extraoral scanners. However, the extraoral scanners showed substantially higher precision measurements for the cross-arch measurement. Surface topography did not correlate to precision. Rather, precision correlated with the scanning mechanism. For a quadrant scanning, both intraoral and extraoral scanners are recommended, but extraoral scanners are recommended for a full-arch scanning.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7344681PMC
http://dx.doi.org/10.3390/dj8020052DOI Listing

Publication Analysis

Top Keywords

surface topography
24
extraoral scanners
20
intraoral extraoral
16
topography precision
12
precision measurements
12
extraoral digital
8
digital scanners
8
scanners reference
8
reference model
8
scanners recommended
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!