Objective: We aimed to assess the accuracy of the estimated fetal weight (EFW) to predict the birthweigth (BW) in pregnancies complicated by PPROM.

Study Design: This study was a secondary analysis of a prospective cohort of pregnancies with PPROM. We included singleton pregnancies from 23 to 36 + 6 weeks, mothers from 13 to 46 years of age, and those with an EFW within two weeks of delivery. We excluded pregnancies with complex fetal anomalies and fetal demise. The accuracy of the EFW was determined by the absolute percent difference between BW and EFW (BW-EFW]/BW*100%). T tests and linear regression were performed for statistical analysis.

Results: The mean percent difference of BW vs. EFW was 8.72 ± 6.94%. The EFW was more accurate (8.24 ± 6.81 vs. 13.31 ± 6.88%,  = .027) and had more measurements with a absolute difference < 10% (70% vs. 30%;  = .034) when performed within seven days of delivery. The EFW accuracy decreased with anhydramnios (11.37 ± 7.06 vs. 7.69 ± 6.77%,  = .020), but the measurements with an absolute difference <10% was not significantly different ( = .27) with anhydramnios.

Conclusion: In PPROM, the EFW within seven days to delivery by Hadlock accurately predicts the birthweight with a mean absolute difference of 8.2%.

Brief Rationale: There are a limited number of studies evaluating the accuracy of the EFW in pregnancies with PPROM in the last four decades.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14767058.2020.1769593DOI Listing

Publication Analysis

Top Keywords

estimated fetal
8
fetal weight
8
percent difference
8
difference efw
8
measurements absolute
8
absolute difference
8
efw
7
pregnancies
5
accuracy
4
weight accuracy
4

Similar Publications

Background: Given the distinctive physiological characteristics of pregnant women, non-pharmacological therapies are increasingly being used to improve depressive and anxiety symptoms. Our objective was to explore and compare the impact of various non-pharmacological interventions in improving depressive and anxiety symptoms, and to identify the most effective strategies for pregnant women with depressive and/or anxiety symptoms.

Methods: We conducted a systematic search of PubMed, Embase, the Cochrane Library, and Web of Science for randomized controlled trials (RCTs) that compared non-pharmacological interventions to usual care, from the inception of each database up to October 5, 2024.

View Article and Find Full Text PDF

Purpose: To develop a rapid, high-resolution and distortion-free quantitative $R_{2}^{*}$ mapping technique for fetal brain at 3 T.

Methods: A 2D multi-echo radial FLASH sequence with blip gradients is adapted for fetal brain data acquisition during maternal free breathing at 3 T. A calibrationless model-based reconstruction with sparsity constraints is developed to jointly estimate water, fat, $R_{2}^{*}$ and $B_{0}$ field maps directly from the acquired k-space data.

View Article and Find Full Text PDF

The incidence for congenital heart block is estimated as high as 1 in 15,000 live births. Up to 90% of cases of congenital heart block, in which there is no anatomical abnormalities, are attributed to maternal systemic lupus erythematous or Sjögren's disease. 50% of these mothers are asymptomatic at time of diagnosis.

View Article and Find Full Text PDF

Whole examination AI estimation of fetal biometrics from 20-week ultrasound scans.

NPJ Digit Med

January 2025

School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK.

The current approach to fetal anomaly screening is based on biometric measurements derived from individually selected ultrasound images. In this paper, we introduce a paradigm shift that attains human-level performance in biometric measurement by aggregating automatically extracted biometrics from every frame across an entire scan, with no need for operator intervention. We use a neural network to classify each frame of an ultrasound video recording.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the safety and efficacy of vacuum-induced intrauterine balloon tamponade (vIBT) using the modified Bakri system in a clinical setting.

Materials And Methods: This single-center observational study included women who had undergone vIBT for primary postpartum hemorrhage (PPH). Vacuum induction at 60 kPa in the uterus was continued for 1 h with 50-100 ml saline, and the balloon was promptly removed after the protocol was completed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!