Our distortion correction method for diffusion-weighted breast images was applied to clinical studies to evaluate its practicality. We used b values of 0 and 1500 s/mm and dynamic images captured after injecting the contrast medium for magnetic resonance imaging (MRI). This method is based on non-rigid image registration, and dispenses with multiple scans, reducing examination time and patient burden. Image correction included the following: matrix size matching; segmentation; edge detection; non-rigid image registration between T2-weighted images with fat suppression and b0 images; and image warping of b1500 images. Significant differences were noted for all combinations of cross-correlation coefficients of whole-breast images between with and without correction, and no significant differences for apparent diffusion coefficients. The percentage differences were not significant for cross-correlation coefficients, with and without correction, calculated for various sizes, positions, and types of lesions of high-intensity regions. In conclusion, our distortion correction method is effective for clinical breast MRI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12194-020-00568-1 | DOI Listing |
Sci Rep
January 2025
Department of Electronic Engineering, Hanyang University, Seoul, 04763, South Korea.
This paper presents novel MIMO microstrip patch antennas with dimensions of 40 × 80 × 1.6 mm³ incorporating a decoupling and pattern correction structure (DPCS) designed to mitigate mutual coupling and radiation pattern distortion, operating within 3.6-3.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
December 2024
University of Houston, Department of Physics, Houston, Texas, United States.
Purpose: Photon counting detectors offer promising advancements in computed tomography (CT) imaging by enabling the quantification and three-dimensional imaging of contrast agents and tissue types through simultaneous multi-energy projections from broad X-ray spectra. However, the accuracy of these decomposition methods hinges on precise composite spectral attenuation values that one must reconstruct from spectral micro-CT. Errors in such estimations could be due to effects such as beam hardening, object scatter, or detector sensor-related spectral distortions such as fluorescence.
View Article and Find Full Text PDFWorld J Clin Cases
December 2024
Department of Ophthalmology, Tung Wah Eastern Hospital, Hong Kong 999077, China.
Upper lid blepharoplasty is a surgical procedure that requires meticulous planning and execution. It is not a standalone procedure but can be combined with ptosis correction surgery. Prior to surgery, thorough lid examinations are essential to determine the appropriate approaches.
View Article and Find Full Text PDFClin Neuroradiol
December 2024
Université Lyon I, Université Claude Bernard, Lyon, France.
Purpose: This study aimed to characterize spinal cord microstructure in healthy subjects using high angular resolution diffusion imaging (HARDI) and tractography.
Methods: Forty-nine healthy subjects (18-50 years, divided into 2 age groups) were included in a prospective study. HARDI of the cervical spinal cord were acquired using a 3T MRI scanner with: 64 directions, b‑value: 1000s/mm, reduced field-of-view (zonally magnified oblique multi-slice), and opposed phase-encoding directions.
Elife
December 2024
RNA Therapeutics Institute, University of Massachusetts Chan Medical School, Worcester, United States.
Images taken by transmission electron microscopes are usually affected by lens aberrations and image defocus, among other factors. These distortions can be modeled in reciprocal space using the contrast transfer function (CTF). Accurate estimation and correction of the CTF is essential for restoring the high-resolution signal in cryogenic electron microscopy (cryoEM).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!