Abutment screw torque changes with straight and angled screw-access channels.

J Prosthet Dent

Professor and Director, Advanced Dental Education Program in Implant Dentistry, School of Dentistry, Loma Linda University, Loma Linda, Calif.

Published: April 2021

Statement Of Problem: Angle-correcting options allow the use of screw-retained implant prostheses in situations where an implant has been placed with a facial inclination. However, manufacturers have different recommended torque values, and it is unclear whether the performance of these designs is equivalent to that of the traditional screw-retained crowns (SRCs) when subjected to cyclic loading forces.

Purpose: The purpose of this in vitro study was to compare torque differences between conventional straight-line screw access and angulated access SRCs before and after simulated functional loading.

Material And Methods: Five groups consisting of 10 SRCs and implants were formed: Nobel Biocare zirconia crowns with 20-degree access channels (NB-20); Dynamic Abutment Solution zirconia crowns (DA-20) with 20-degree access channels; Core3dcentre angle correction zirconia crowns with 20-degree access channels (C3D-20); Nobel Biocare zirconia crowns with 0-degree access channels (NB-0); and gold alloy crowns cast to Nobel Biocare Gold-Adapt abutments (GA-0). Each specimen underwent thermocycling before cyclic loading. A preload torque based on the manufacturer's recommendation was applied to each crown placed on an implant. Reverse torque measurements were obtained for each specimen before cyclic loading. Each implant-abutment assembly was then cyclic loaded at 0 to 100 N at 10 Hz for 1 million cycles. Reverse torque measurements were obtained after cyclic loading and the percentage difference calculated.

Results: No significant percentage torque loss differences were observed between the 0-degree and 20-degree SRCs after cyclic loading. No significant differences were seen among the angulated access channel crowns. DA-20 and C3D-20 specimens had significantly higher torque loss compared with the NB-0 group. The C3D-20 group reported the largest percentage torque loss (34.5%) among the angulated access screw channel groups. The GA-0 group reported the largest percentage torque loss of all the groups (35.9%). No crown mobility or other complications were observed in any of the groups after cyclic loading.

Conclusions: Angulated access channel crowns performed comparably with conventional straight-line screw access SRCs with regard to percentage torque values after cyclic loading. Angulated access channel crowns with lower manufacturer recommended torque values had higher percentage torque differences.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2020.01.018DOI Listing

Publication Analysis

Top Keywords

cyclic loading
24
angulated access
20
percentage torque
20
zirconia crowns
16
access channels
16
torque loss
16
torque
13
torque values
12
nobel biocare
12
20-degree access
12

Similar Publications

In situ growth of defective ZIF-8 on TEMPO-oxidized cellulose nanofibrils for rapid response release of curcumin in food preservation.

Carbohydr Polym

March 2025

Liaoning Key Lab of Lignocellulose Chemistry and BioMaterials, Liaoning Collaborative Innovation Center for Lignocellulosic Biorefinery, College of Light Industry and Chemical Engineering, Dalian Polytechnic University, Dalian 116034, China. Electronic address:

Uncontrolled release of active agents in active packaging reduces antimicrobial efficacy, hindering the effective protection of perishable products from microbial infection. Herein, a novel defective engineering was proposed to design defective and hollow ZIF-8 structures grown on TEMPO oxidized cellulose nanofibrils (TOCNFs) and use them as fast-reacting nanocarriers for loading and controlled release curcumin (Cur) in sodium alginate (SA) active packaging systems (CZT-Cur-SA). By employing stable chelation between tannic acid (TA) and ZIF-8 zinc ions, the connections between zinc ions and imidazole ligands were severed to form a loose and hollow structure, which facilitates the rapid reaction and release of active ingredients triggered by pH changes in the microenvironment.

View Article and Find Full Text PDF

Purpose: To investigate how varying ferrule heights and the number of glass fiber posts affect fracture resistance and behavior of endodontically treated maxillary first premolars with substantial loss of tooth structure.

Materials And Methods: Twenty-four extracted endodontically treated human maxillary first premolars were divided into three groups (n = 8) based on ferrule height and post number. The groups were as follows: premolars of 2 mm ferrule height that were restored with single posts (control group), premolars of 0.

View Article and Find Full Text PDF

Purpose: To evaluate the maximal load to failure, cyclic displacement, stiffness, and modes of failure of onlay subpectoral biceps tenodesis with an intramedullary unicortical metal button (MB) versus an inlay, all-suture Caspari-Weber (CW) technique.

Methods: Sixteen matched paired human cadaveric proximal humeri were randomly allocated for subpectoral BT with either CW or MB using a high-strength suture (N = 16; 8 male, 8 female, mean age = 82.5 years, range 62-99 years).

View Article and Find Full Text PDF

Rubber is widely used in situations involving cyclic loads, and the influence of temperature on rubber properties is particularly pronounced under cyclic loading. In this study, mechanical property tests and crack propagation tests of carbon black-filled hydrogenated nitrile butadiene rubber were conducted at four different operating temperatures. Based on the results of the crack propagation tests, the temperature-dependent characteristics of the Paris-Erdogan parameters and strain energy density were clarified.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!